Nomenclature - York MagnaDRY DK-07 Series Installation Manual

Single package air conditioners and single package gas/electric units
Table of Contents

Advertisement

335224-BIM-B-1208

NOMENCLATURE

7.5-12.5 Ton Single Package Model Number Nomenclature
D K -10 N18 A T A AA 3 0 1 2 4 A
Product Category
D = A/C, Single Pkg., R-410A
Product Identifier
K = Reheat
Nominal Cooling Capacity
-07 = 7.5 Ton
-10 = 10.0 Ton
-12 = 12.5 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. No heat installed
Gas Heat Options
N12 = 120 MBH Input Aluminized Steel
N18 = 180 MBH Input Aluminized Steel
N24 = 240 MBH Input Aluminized Steel
S12 = 120 MBH Input Stainless Steel
S18 = 180 MBH Input Stainless Steel
S24 = 240 MBH Input Stainless Steel
Electric Heat Options
E09 = 9 KW
E18 = 18 KW
E24 = 24 KW
E36 = 36 KW
E54 = 54 KW
Airflow
A = Std. Motor
B = Std. Motor/Econo./Barometric Relief (Downflow
Only)
C = Std. Motor/Econo./Power Exhaust (Downflow Only)
D = Std. Motor/Motorized Damper (Downflow Only)
E = Std. Motor/Horizontal Economizer (No Baro.)
F = Std. Motor/Slab Econo./Power Exhaust
(Downflow Only)
G = Std. Motor/Slab Econo./Barometric Relief
(Downflow Only)
N = Hi Static
P = Hi Static /Econo./Barometric Relief
(Downflow Only)
Q = Hi Static /Econo./Power Exhaust
(Downflow Only)
R = Hi Static /Motorized Damper (Downflow Only)
S = Hi Static /Horizontal Economizer (No Baro.)
T = Hi Static /Slab Econo./Power Exhaust
(Downflow Only)
U = Hi Static /Slab Econo./Barometric Relief
(Downflow only)
6
Product Generation
4 = Fourth Generation
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
Voltage
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
T = 208/230-3-60
X = Options 3 & 5
W = 460-3-60
Y = Options 4 & 5
X = 575-3-60
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Product Style
A = Style A
B = Style B
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/ModLinc
2" Pleated filters
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Shipping Bag
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Additional Options
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
Johnson Controls Unitary Products

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnadry dk-10 seriesMagnadry dk-12 series