TK-7302/7302
V
/7302H/7302H
(
)
Common Section
Item
Condition
1. Setting
1) Power supply voltage
DC power supply terminal
: 13.6V
2. Rx Assist
1) CH: RX low
(Auto)
CH: RX low'
(Narrow)
CH: RX center
CH: RX high'
CH: RX high
3. Tx Assist
1) CH: TX low
(Auto)
CH: TX low'
(Narrow)
CH: TX center
CH: TX high'
CH: TX high
Transmit
4. VCO lock
1) CH: RX low
voltage
CH: RX low'
CH: RX center
• RX
CH: RX high'
CH: RX high
• TX
2) CH: TX low
CH: TX low'
CH: TX center
CH: TX high'
CH: TX high
Transmit
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: TX center
(Narrow)
Transmit
2. High Power
1) CH: TX low
(Auto)
CH: TX low'
(Narrow)
CH: TX center
CH: TX high'
• TK-7302/
CH: TX high
7302(V)
Transmit
• TK-7302H/
7302H(V)
30
V
(
)
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
TX-RX
CV
meter
DVM
Measurement
Test-
Unit
Terminal
Unit
equipment
Frequency
ANT
counter
Power
meter
Adjustment
Parts
Method
FPU
"Voltage Level"
2.5V±0.2V
indicator on the PC
window shows VCO
lock voltage.
Change the adjust-
ment value to get
VCO lock voltage
within the limit of
the specifi ed volt-
age.
Note:
Confi rm the VCO
lock voltage approxi-
mately 3 seconds
after the adjustment
value is changed.
Check
2.5V±0.2V
Adjustment
Parts
Method
FPU
Adjust to center
Within ±50Hz
frequency
25W
±1.0W
8.0A or less
50W
±2.0W
14.0A or less
Specifi cations / Remarks
Specifi cations / Remarks