5.7.2. Preset CH write condition

1) AC on time on only one after assembled automatically
2) In case of PAL model, CH recover on SVC OSD manually
In case of NTSC model, default channel : -> After In-Stop /
Facotry reset
TV : 2,3,4,5,6,7,8,9,10,11,12,13,14,30,51,55,63 CATV :
15,16,17,55,95
5.7.3. Preset CH erase condition
1) In-Stop key

5.8. Internal press test

No
Item
Vallue
1. Dielectric Voltage(AC<->FG)
2. Dielectric Voltage(Without FG)

5.9. Motion Remote controller Inspection

5.9.1. Equipment : Motion remote controller for
test, IR-KEY-CODE remote controller for
test
Check
(Recommend : Change battery for every
Lot.)
5.9.2. Process
1) Push "Mute" or " START" key for pairing between TV-set
and motion remote controller.
2) Push "OK" or "Enter" key, you can see the Cursor on
screen.
3) Push "Vol+" or "STOP" key, Disconnect Pairing.
Copyright
LG Electronics. Inc. All right reserved.
Only for training and service purposes
Unit
Remark
1.5
kV
At 100mA for 1sec(Line)
1.5
At 100mA for 1min(OQC)
3
kV
At 100mA for 1sec(Line)
3
At 100mA for 1min(OQC)
battery
before

5.10. 3D Function test

5.10.1. Equipment : Pattern Generator MSPG-
3233, HDMI mode 37, pattern No. 81
5.9.2. Process
1) Connect HDMI (HDMI mode 371, Pattern No. 81)
2) Insert 3D Mode, Select side by side mode.
3) Without 3D-glasses, Like below figure.
test.
4) With 3D left-glass, Like below figure. (Center is RED)
5) With 3Dright-glass, Like below figure.(Center is Blue)