Baxi Combi 130 HE User Operating Instructions Manual page 7

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

5mm Min
Fig. 8
500mm
For Servicing
Purposes
5mm
In Operation
Fig. 9
490mm
5mm Min
200mm
850mm
200mm
320mm
3.0 Clearances and Check List
3.1
Clearances around the Boiler
(Figs. 8 & 9)
1. The minimum clear spaces needed around the
boiler measured from the casing are as follows:
Top
-
Bottom
-
Both sides -
Front
-
-
2. These areas must not be obstructed in any
way. Blocking the clearance spaces may
result in the boiler overheating and damage
may occur.
3. The gas burning compartment of your boiler is
completely sealed from the room in which it is
fitted. Products from the combustion of gas are
vented to the outside through the flue terminal
which must be kept free from obstruction as this
would interfere with the correct operation of the
boiler.
4. Where the appliance is installed in a
cupboard or compartment no air vents are
required. The label affixed to the front of the
boiler must not be removed. The information will
be required by service engineers in the future.
The compartment should be large enough to
house the boiler and ancillary equipment only.
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
3.2
Check List
(1 in 20)
1. If a fault develops, or is suspected, call your
Service Engineer as soon as possible.
2. Go through the following check list before you
make contact.
a)
Is the electricity supply on ?
b)
Is the On/Off/Reset button on (Not showing
00) and set for both Central Heating and
Domestic Hot Water ? (Showing On)
c)
Is the red "Flame Failure" indicator
illuminated ? if so, press the On/Off/Reset
Button (It may also be necessary to turn the
power off for 10 seconds)
d)
Is the gas supply on ?
e)
Is the mains water supply turned on ?
f)
Are the boiler temperature controls set high
enough ?
g)
Is the time clock (if fitted) calling for central
heating ?
h)
Is the room thermostat (if fitted) set high
enough ?
i)
Are the radiator valves open ?
200mm
200mm
5mm
500mm
(For Servicing)
5mm
(In Operation)
7