Disassembly
To avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitors
before following any disassembly procedure.

Capacitor / Diode

1. See figure 3, page 33 for location.
2. Remove outer case, see "Outer Case" procedure.
3. Discharge capacitor and remove wire terminals from
capacitor.
4. Remove screws securing capacitor mounting bracket
to oven chassis.
5. Loosen screws securing capacitor strap to capacitor.
6. Reverse procedure to reassemble.

Convection Box

1. See "Component Location" Figure 5, page 34.
2. Remove back panel, see "Back Panel" procedure.
3. Remove inlet duct assembly, See "Inlet Duct
Assembly" procedure.
4. Remove control board bracket assembly, see "Control
Board Bracket Assembly" procedure.
5. Disconnect and label wire terminals from Heating
Element, TCO, and Temperature Sensor.
6. Remove screws securing thermal limiter to convection
box.
7. Remove screws securing convection box to plenum
box.
8. Remove convection box from unit.
9. Remove bolt securing fan blade and pull fan blade off.
10.Remove screws securing convection motor to heater
box.
11. Reverse procedure to reassemble.

Convection Element

1. Remove convection box, see "Convection Box"
procedure (located above).
2. Remove screws securing convection element to
convection box.
3. Reverse procedure to reassemble.
NOTE: Center convection element around convection
fan blade and spin fan blade to ensure it does
not hit convection element.
©2006 Maytag Services
!
WARNING

Thermal Limiter

1. See figure 3, page 33 for location.
2. Remove outer case, see "Outer Case" procedure.
3. Disconnect and label wire terminals from limiter.
4. Remove screws securing thermal limiter to convection
box.
5. Loosen and remove RTV sealant securing limiter to

plenum box.

6. Reverse procedure to reassemble.
NOTE: When reinstalling and securing limiter tube into
plenum box. Lower limiter tube into the plenum
box until 1/4" of limiter tube is left outside the
plenum box and secure with RTV. Perform
operational check on unit to ensure there is no
air leakage around the limiter tube.

Fuse

1. See "Component Location" Figure 2, for location.
2. Remove outer case.
3. Replace fuse and reassemble in reverse order.

Power Cord

1. See "Component Location" Figure 3, for location.
2. Remove outer case and back panel.
3. Disconnect wiring.
4. Remove strain relief by compressing with pliers.
5. Remove power cord.
6. Reassemble power cord in reverse order.
Line Filter (50 Hz Models Only)
1. See "Component Location" Figure 3, for location.
2. Remove outer case and back panel.
3. Disconnect wiring.
4. Remove power cord strain relief by compressing with
pliers.
5. Remove power cord.
6. Remove screws securing line filter and remove.
7. Reassemble power cord in reverse order.