Cook Condition - Amana AMH20 Service Manual

Commercial combination/ convection microwave oven
Table of Contents

Advertisement

60 Hz Troubleshooting Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
SCHEMATIC CONDITION: DOOR CLOSED
L1
25A
25A
HEATER
MAG
FUSE 2
FUSE 1
TEMP
LIMITER
2
6
4
8
CAUTION:
DO NOT REMOVE WIRE FROM TRIAC TERMINAL
T2 DURING TESTING. THIS WILL CAUSE
HV BOARD TO SHORT OUT.
INTERLOCK SWITCH SCHEMATIC
DOOR CLOSED
2
3 SECONDARY
4
5 PRIMARY
7
8 MONITOR
12
!

Cook Condition

208/230V 60HZ
GND
POWER BOARD
J8-1
POWER BO ARD
J8-2
J8-3
J1-1
J1-2
K1
J2-5
NO
MAG 2
TCO
E4
E5
K4
(208)
J3-3
NO
NC
J3-1
NO
K5
(230)
360
½ W
RESISTOR
J2-1
J2-3
NO
J2-2
NO
K3
J2-4
NO
K2
RADIANT HEATER
(LH)
K7
J4-5
J4-6
NO
NC
J4-7
NO
K6
K9
(208)
E6
J4-1
E7
NO
J4-2
NC
J4-3
NO
J4-4
K8
(230)
W ARNING
L2
DATA KEY
BOARD
E1
E2/E3
CURRENT
SENSE
J5
J8-4
J8-6
J8-7
SHIELDED
CABLE
HALFWAVE
CONTROL
PROTECTION
RTD
TCO
BOARD
NC
E5
RLY1
MAG 1
TCO
NC
RLY2
CONVECTION FAN
NO
M2
RLY1
AUTO TRANSFORMER
CAPACITOR
230
208
CONVECTION HEATER
(REAR)
RADIANT HEATER
(RH)
7
8
INTERLOCK
(M ONITO R)
POWER TRANSFORMER
230
208
16023463
CONTROL/TEMPERATURE
CONVECTION (FUSE 2)
MICROWAVE (FUSE 1)
UPPER
SPEAKER
SWITCH
J1-4
J1-2
J1-1
BOARD
J4
J2-4
J2-2
J2-1
DISPLAY
J1-3
4
BOARD
J5
5
J1-1
DOOR
INTERLOCK
(PRIMARY)
LOWER
SWITCH
E2
J7-6
J7-5
J7-5
POWER
BOARD
TRIAC (TR1)
G
G
BLOWER
T2
T1
NO
(RIGHT)
RLY2
SNUBBER
120
COM
COOLING FAN
M1
M3
STIRRER
J7-4
J7-3
J7-3
POWER
BOARD
TRIAC (TR2)
G
G
HEATER
T2
T1
(M IDDLE)
SNUBBER
INTERLOCK
(SECONDARY)
J7-2
J7-1
J7-1
POWER
BOARD
TRIAC (TR3)
G
G
MAGNETRON
T1
T2
(LEFT)
COM
SNUBBER
SNUBBER
DANGER
HIGH VOLTAGE
©2006 Maytag Services
2
3

Advertisement

Table of Contents
loading