Travis Industries 864 TRV GS2 Installation Manual page 56

Built-in direct vent fireplace natural gas or propane residential or mobile home
Hide thumbs Also See for 864 TRV GS2:
Table of Contents

Advertisement

56
Finalizing the Installation
4
Install the LP pilot orifice following the instructions below.
a.
Use pliers to remove the E-Clip on the pilot assembly.
NOTE: If the clip is especially tight, use a screwdriver or needle-nose pliers to pry loose.
b.
Remove the pilot hood and place it aside.
c.
Unscrew the NG orifice and discard it. Carefully thread the LP orifice into place and tighten.
d.
Replace the pilot hood.
NOTE: the pilot hood has a notch that fits over the tab on the pilot base.
e.
Use pliers to re-install the E-Clip.
f.
Make sure the E-Clip is fully inserted and the pilot hood does not wiggle when in place. The middle tab of
the clip will rest against the pilot base (apex of hexagon) as shown in the illustration. If the clip is fully
inserted and the hood is not fully secure, remove the clip and use pliers to compress the clip slightly then re-
install and verify the hood is tight. The clip may also be compressed while in place, forcing the clip into the
slots on the pilot assembly.
a
d
5
Replace the firebox components. Install the
logs and embers. Replace the glass.
6
Remove and discard the screws (see "a" below)
holding the stock regulator in place (see "b"
below). Remove the stock regulator and gasket
(see "c" below). Place the LP regulator in place,
making sure the pre-fitted gasket (see "c" below)
is in place. NOTE: There is a label on the base of
the regulator knob indicating regulator type (NG or
LP). Secure the regulator with the screws
included with the regulator – tighten to 25 lb-in of
torque (2.82 NM). Place the included label on the
valve body where it can be easily seen to insure
proper identification. NOTE: Leak test this area
after the heater is installed, gas is connected,
and the main burner is lit.
7
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve.
Travis Industries
(for qualified installers only)
b
e
4121102
c
35
5/32" Hex
f
a
b
d
Orifice Identification:
LP (Propane) Orifice
35
NG (Natural Gas) Orifice
62
T-20 Torx or
Slotted Screwdriver
c
100-01301