Make sure the inlet water supply is turned off, then supply power to the timer. The display will power up flashing
"12:00 PM" and the motor will energize and cycle the control, without stopping, to the home position. This is
required to ensure that the control is in the home position.
The timer uses four buttons:
1. STATUS:
Advance timer through display options.
2. PLUS SIGN "+":
Increase the setting.
3. MINUS SIGN "-":
Decrease the setting.
4. REGEN.:
Initiate a manual regeneration.
PROGRAMMING THE OPTION SETTINGS
The microprocessor has several programming options that can be changed for various additional functions. Listed
are the functions for the programming options used on the Culligan Medallist Series
Dip Switch
1
2
Delay or Immediate Regeneration
3
Softener or Filter
4
Time Clock Backup
5
English or Metric
6
12 or 24 Hour Clock
7
1
Service or Test Mode
P r e s s
a n d
h o l d
display. "dIP1" will blink for 3 seconds and then the display will
show the status of this option (SEr or tES). Toggle the feature
with the "+" or "-" key.
Note: Pressing "STATUS" after changing option to test mode
will place the control in test mode. After testing is complete
press and hold "STATUS" for 3 seconds to return to "dIP1"
setting. Placing the unit in test mode will not change any of the
programmed values.
2
Delay or Immediate Regeneration
Press the "STATUS" key. The display will blink "dIP2" for 3
seconds and then show the current status. Toggle between
"DEL" (Delay) and "Id" (Immediate) with the "+" or "-" key.
Note: Changing this setting will not change any of the
programmed value with the exception that Step #2, time of
regeneration will be ignored when set to immediate.
3
Softener or Filter
Press the "STATUS" key. The display will blink "dIP3" for 3
seconds and then show the current status. Toggle between
"SOF" (Softener) and "FIL" (Filter) with the "+" or "-" key.
Note: Changing this setting will cause the unit to load the
Filter or Softener defaults.
4
Timeclock Backup
Press the "STATUS" key. The display will blink "dIP4" for 3
FIG. 3 - Circuit Board Display
Function
Service or Test
3/4" or 1" Meter
t h e
" S T A T U S "
Default Position
Service
Delayed Regeneration
Softener
OFF
English
12 Hour
3/4" Meter
k e y
u n t i l
" d I P 1 "

Programming

control.
a p p e a r s
i n
t h e
del
sof
PROGRAMMING
11