Lighting Burner; To Turn Off Gas - MHSC CDVR33 Installation And Operating Instructions Manual

Cdv series direct vent gas fireplace
Table of Contents

Advertisement

MIllIVOlT OpERATING INSTRuCTIONS
MAIN BuRNER SWITCh
The "ON/OFF/RS" switch for the main burner can be found behind door of the fireplace. This switch
allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure
the button is in the "ON" position to light the main burner. Figure 53
lIGhTING ThE BuRNER
Depress and turn the knob counterclockwise
less than four (4) seconds for the burner to ignite.
pIlOT pOSITION
Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. Figure
55
Figure 53 -
On/Off/RS Switch
Depress and turn knob clockwise
The control is fitted with a safety interlock
device which prevents unsafe ignition of the
pilot burner after the control knob has been
turned to the oFF position. The knob may
only be rotated back to the PIloT position
after the safety magnet has been released
(approximately 60 seconds). You will hear a
"click" when the safety magnet releases.
69D0023

lIGhTING BuRNER

P I L
O T
Figure 54 - On Position

TO TuRN OFF GAS

to "OFF" position. Figure 56
CDV Series Gas Fireplace
to the "ON" position. Figure 54. It will take
Figure 55 - Pilot Position
Figure 56 - Off Position
T
P I L
O T
P I L
O T
39