MHSC CDVR33 Installation And Operating Instructions Manual

Cdv series direct vent gas fireplace
Table of Contents

Advertisement

Installation and Operating Instructions

CDVR33, CDVT33, CDVR36, CDVT36,
CDVR42, CDVT42, CDVR47, CDVT47
WARNINGS
IF ThE INFORMATION IN ThESE INSTRuCTIONS ARE
NOT FOllOWED ExACTly, A FIRE OR ExplOSION
MAy RESulT CAuSING pROpERTy DAMAGE,
pERSONAl INjuRy OR lOSS OF lIFE.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WhAT TO DO IF yOu SMEll GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
– Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause injury or
property damage. Refer to this manual. For assistance
or additional information consult a qualified installer,
service agency or the gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
* Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
READ BEFORE INSTAllING. SAVE ThESE INSTRuCTIONS
CDV SERIES
Direct Vent Gas Fireplace
Models:
CDVT
CDVR
DuE TO hIGh TEMpERATuRES, ThE
ApplIANCE ShOulD BE lOCATED OuT
OF TRAFFIC AND AWAy FROM FuRNITuRE
AND DRApERIES.
ChIlDREN AND ADulTS ShOulD BE
AlERTED TO ThE hAZARDS OF hIGh
SuRFACE TEMpERATuRE AND ShOulD
S TAy AWAy TO AV O I D B u R N S O R
ClOThING IGNITION.
y O u N G C h I l D R E N S h O u l D B E
SupERVISED WhEN ThEy ARE IN ThE
SAME ROOM AS ThE ApplIANCE.
ClOThING OR OThER FlAMMABlE
MATERIAl ShOulD NOT BE plACED ON
OR NEAR ThE ApplIANCE.
KEEp ThE ROOM AREA ClEAR AND
FREE FROM COMBuSTIBlE MATERIAlS,
GASOlINE, AND OThER FlAMMABlE
VApORS AND lIquIDS.
69D0023 1/09 Rev. 8

Advertisement

Table of Contents
loading

Summary of Contents for MHSC CDVR33

  • Page 1: Installation And Operating Instructions

    CDV SERIES Direct Vent Gas Fireplace Installation and Operating Instructions Models: CDVR33, CDVT33, CDVR36, CDVT36, CDVR42, CDVT42, CDVR47, CDVT47 CDVT WARNINGS IF ThE INFORMATION IN ThESE INSTRuCTIONS ARE NOT FOllOWED ExACTly, A FIRE OR ExplOSION MAy RESulT CAuSING pROpERTy DAMAGE, pERSONAl INjuRy OR lOSS OF lIFE.
  • Page 2: Table Of Contents

    Lighting Pilot for the First Time....37 Lighting Pilot..........38 Before You Start ..........6 Fireplace Framing - CVDR36 and CDVR33.. 7 Lighting Burner ..........39 Fireplace Framing - CVDT36 and CDVT33 .. 8 To Turn Off Gas ........... 39 Fireplace Dimensions........
  • Page 3: Important Safety Information

    IMpORTANT SAFETy INFORMATION CDV Series Gas Fireplace INSTAllER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous. • Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning. This fireplace is a vented product. This fireplace must •...
  • Page 4 IMpORTANT SAFETy INFORMATION CDV Series Gas Fireplace Continued from page 3 IMpORTANT: 10. Have venting system inspected annually by a quali- plEASE READ ThE FOllOWING CAREFully fied service person. If needed, have venting system It is normal for fireplaces fabricated of steel to cleaned or repaired.
  • Page 5: Product Features

    pRODuCT FEATuRES and CODE AppROVAl CDV Series Gas Fireplace pRODuCT SpECIFICATIONS • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance is approved for bedroom or bedsitting room installations.
  • Page 6: Pre-Installation Information

    GAS Manifold Press: (W.C.) 3.5" Manifold Press: (W.C.) 10" Maximum Supply Pressure 10.5" Maximum Supply Pressure 13" Minimum Supply Pressure 4.5" Minimum Supply Pressure 11" Model Number CDVR33 CDVT33 CDVR36 CDVT36 Natural Propane Natural Propane Natural Propane Natural Propane Max. BTU/hr Input...
  • Page 7: Fireplace Framing

    FIREplACE FRAMING CDV Series Gas Fireplace FIReBox FRAMING FoR CDVR33/36 Do not fill spaces around firebox with Firebox framing can be built before or after the appli- insulation or other materials. This ance is set in place. Construct firebox framing following Figure 2 and the chart below for your specific installation could cause a fire.
  • Page 8 FIREplACE FRAMING CDV Series Gas Fireplace FIReBox FRAMING FoR CDVT33/36 Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 3 and the chart below for your specific installation requirements. See Figure 4 on Page 10 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs.
  • Page 9: Fireplace Dimensions

    " Figure 4 - Framing Dimension CDVT Series Fireplace Dimensions Framing Dimension " " Nailing Tabs Will Accommodate Finishing " or " Finishing Material Spacers CDVR33 CDVR36 CDVR42 CDVR47 " " " " " 35" " " " " "...
  • Page 10: Fireplace Location

    pRE-INSTAllATION INFORMATION CDV Series Gas Fireplace FIREplACE lOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e.
  • Page 11: Clearances

    ClEARANCES CDV Series Gas Fireplace ClEARANCES TO COMBuSTIBlES Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance. 71"...
  • Page 12: Securing Fireplace To Floor Or Framing

    SECuRING FIREplACE TO FlOOR OR FRAMING CDV Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 8. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2"...
  • Page 13: Installation Information

    INSTAllATION INFORMATION CDV Series Gas Fireplace FINIShING MATERIAl NOTE: Any wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction. Never obstruct or modify the air inlet or outlet grills (louvers). This may create a fire hazard. Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to °...
  • Page 14: Vent Installation

    VENT INSTAllATION CDV Series Gas Fireplace REAR VENT INSTAllATION This fireplace must be vented to the outside. The venting system must NeVeR be attached to a chimney serving a separate solid fuel burning appliance. each gas appliance must use a separate vent system. Do not use common vent systems. Horizontal sections of this vent system A Minimum of 3"...
  • Page 15: Top Vent Installation

    VENT INSTAllATION CDV Series Gas Fireplace TOp VENT INSTAllATION This fireplace must be vented to the outside. The venting system must NeVeR be attached to a chimney serving a separate solid fuel burning appliance. each gas appliance must use a separate vent system. Do not use common vent systems. A Minimum of 3" Clearance Horizontal sections of this vent system require a to the Top Is Required Along minimum of 3" clearances to combustibles at the...
  • Page 16: Installation Planning

    VENT INSTAllATION CDV Series Gas Fireplace INSTAllATION plANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
  • Page 17 VENT INSTAllATION CDV Series Gas Fireplace FOR hORIZONTAl TERMINATION Inside Corner Detail Fixed Closed Opera- Fixed Closed Operable Vent Terminal Air Supply Inlet Area Where Terminals Not Permitted Figure 11 - Horizontal Vent Termination Location MINIMuM DISTANCES A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305 mm) minimum]. B = Clearance to window or door that may be opened [*12"...
  • Page 18 VENT INSTAllATION CDV Series Gas Fireplace TERMINATION ClEARANCES FOR BuIlDINGS WITh COMBuSTIBlE AND NONCOMBuSTIBlE ExTERIORS Combustible = 6" (152mm) Noncombustible = Combustible = 2” (51mm) 6" (152mm) Noncombustible = 2” (51mm) Inside Corner Outside Corner C = Maximum depth of 48" (1219mm) for alcove location D = Minimum width for back wall of alcove location...
  • Page 19: Rear (Through The Wall) Applications

    VENTING INSTAllATION CDV Series Gas Fireplace ReAR (THRoUGH THe WAll) APPlICATIoNS When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m).
  • Page 20 A vinyl siding standoff must be used with the Simpson or Silkirk Horizontal Termination on vinyl, stucco or wood- clad exterior walls. MHSC termination does not require a standoff. Apply non-hardening mastic around outside edge of the standoff instead of the vent cap assembly. Figure 18 5.
  • Page 21: Horizontal Termination Configuration

    VENT INSTAllATION CDV Series Gas Fireplace hORIZONTAl TERMINATION CONFIGuRATIONS Since it is very important that the venting system maintain its bal- ance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The Vent Graph, showing the relationship between vertical and hori- zontal side wall venting, will help to determine the various dimensions allowable. Figure 20 NOTE: Horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue unless the vertical run is feet or higher (top vent units only), the clearances for the horizontal run is 1"...
  • Page 22 VENT INSTAllATION CDV Series Gas Fireplace hORIZONTAl TERMINATION CONFIGuRATION 90° (Continued) • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36". Figures 21 and 22, Page 20. This does not apply if the 90° elbows are used to increase or redirect a vertical rise.
  • Page 23: Below Grade Installation

    VENT INSTAllATION CDV Series Gas Fireplace BElOW GRADE INSTAllATIONS When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.
  • Page 24: Vertical Through-The-Roof Installation

    VENT INSTAllATION CDV Series Gas Fireplace VeRTICAl (THRoUGH-THe-RooF) APPlICATIoNS This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 28 NOTE: Horizontal sections of this vent system require a minimum of 3"...
  • Page 25: Installation For Vertical Termination

    VENT INSTAllATION CDV Series Gas Fireplace INSTAllATION FOR VERTICAl TERMINATION 1. Determine the route your vertical venting will take. If ceiling Roof joist, roof rafters or other framing will obstruct the venting Flashing system, consider an offset. Refer to Figure 30 to avoid cut- ting load bearing members.
  • Page 26: Cathedral Ceiling Installation

    VENT INSTAllATION CDV Series Gas Fireplace 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof). The 9 "x9 1/ 2 " (241 mm x 241 mm) hole must be measured on the horizontal. Actual length may be larger depending on the pitch of the roof.
  • Page 27: Flex Vent Installation

    FlEx VENT INSTAllATION CDV Series Gas Fireplace 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. All restrictions, clearances and allowances that per- tain to the rigid piping apply to the flexible venting. Flex UL1777 Flex Vent kits may not be modified. Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer's approved flex to pipe adapters.
  • Page 28 D. Attaching flexible venting to vertical termination assemblies. 1. When using Simpson pipe, an MHSC flex-to-pipe adapter (FPA) and/or rigid pipe section(s) is required to connect the flexible vent assembly to the vertical termination by using three (3) self-penetrating screws.
  • Page 29: Fireplace Installation

    FIREplACE INSTAllATION CDV Series Gas Fireplace ChECK GAS TypE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. INSTAllING GAS PIPING To FIRePlACe / BURNeR SYSTeM loCATIoN A qualified installer or service person must connect appliance to gas supply.
  • Page 30 FIREplACE INSTAllATION CDV Series Gas Fireplace only persons licensed to work A manual shutoff valve must be with gas piping may make the installed upstream of the appliance. necessary gas connections to Union tee and plugged 1/8" NPT this appliance. pressure tapping point should be installed upstream of the appliance.
  • Page 31: Checking Gas Pressure

    ChECK GAS pRESSuRE and ElECTRICAl INSTAllATION CDV Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.
  • Page 32: Electrical Installation

    ElECTRICAl INSTAllATION CDV Series Gas Fireplace REMOTE WAll MOuNTED SWITCh A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 43. Do not extend beyond the wall switch wire length provided.
  • Page 33: Electronic Pilot Ignition Wiring

    ElECTRICAl INSTAllATION CDV Series Gas Fireplace ElECTRONIC pIlOT IGNITION WIRING Do not connect 110-120 VAC to the Remote Wall Switch. The appliance Pilot Assembly will malfunction. To Junction Box Spark Sense Ignition Module (Synetek) GREEN WHITE BLACK MAGENTA #5 BLACK WHITE Primary - 120V Electronic Valve Transformer...
  • Page 34: Optional Fan/Blower Systems

    ElECTRICAl INSTAllATION CDV Series Gas Fireplace oPTIoNAl FAN/BloWeR SYSTeMS The junction box for the fan/blower systems has been factory installed. This system requires that 110-120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed. Figure 46. 120VAC Receptacle Junction...
  • Page 35: Glass Removal

    GlASS REMOVAl CDV Series Gas Fireplace GlASS FRAME REMOVAl 1. Remove upper and lower louvers. 2. Release two clamps on bottom of fire- place. Figures 48 and 49. 3. Tilt glass frame out and lift glass frame up until it clears the hook on top of the frame.
  • Page 36: Final Installation

    FINAl INSTAllATION CDV Series Gas Fireplace ROCK WOOl plACEMENT 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool Burner apart into pieces the size of a dime or smaller. NOTE: Embers must be loosely placed to allow proper burner flame.
  • Page 37: Millivolt Operating Instructions

    MIllIVOlT OpERATING INSTRuCTIONS CDV Series Gas Fireplace FOR yOuR SAFETy READ BEFORE lIGhTING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 38: Lighting Pilot

    MIllIVOlT OpERATING INSTRuCTIONS CDV Series Gas Fireplace lIGhTING pIlOT FOR ThE FIRST TIME AppROVED lEAK TESTING METhOD You may check for gas leaks with the following methods only: If using a soap and water solution to test for leaks, • Soap and water solution DO NOT spray solution •...
  • Page 39: Lighting Burner

    MIllIVOlT OpERATING INSTRuCTIONS CDV Series Gas Fireplace lIGhTING BuRNER MAIN BuRNER SWITCh The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 40: Electronic Ignition Operating Instructions

    ElECTRONIC IGNITION OpERATING INSTRuCTIONS CDV Series Gas Fireplace FOR yOuR SAFETy READ BEFORE lIGhTING A. This appliance is equipped with an ignition device (Piezo) which automatically lights If you do not follow these instructions the pilot. Do NOT try to light the burner by exactly, a fire or explosion may result hand.
  • Page 41: Cleaning And Maintenance

    ClEANING AND MAINTENANCE CDV Series Gas Fireplace Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season BuRNER, pIlOT AND CONTROl COMpARTMENT Keep the control compartment, logs, and burner areas surrounding the logs clean by vacu- uming or brushing at least twice a year.
  • Page 42: Vent System

    ClEANING AND MAINTENANCE CDV Series Gas Fireplace VENT SySTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 43: Troubleshooting

    TROuBlEShOOTING CDV Series Gas Fireplace STANDING pIlOT IGNITION SyMpTOM pOSSIBlE CAuSE ACTION 1. Spark ignitor A. Wire disconnected. A. Open door and check to make sure wire is connected to will not light ignitor. pilot after B. Defective ignitor. B. Check for spark at electrode and pilot. If no spark and elec- repeated trode wire is properly connected, replace pilot assembly.
  • Page 44 TROuBlEShOOTING CDV Series Gas Fireplace ElECTRONIC IGNITION START 1. Turn gas supply off. Check: Line voltage (120VAC) 2. Turn ON/OFF switch to “ON” Low voltage transformer (19.5 minimum VAC) Power to module (24V Normal) ON/OFF switch Wiring connections Is there a spark across Unplug ignition lead and ignitor sensor gap? check spark at module...
  • Page 45 TROuBlEShOOTING CDV Series Gas Fireplace GENERAl TROuBlEShOOTING SyMpTOM pOSSIBlE CAuSE ACTION 1. Glass Soots A. Flame impingement on logs A. Install log set per the instructions Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean. Check gas supply.
  • Page 46: Replacement Parts

    IlluSTRATED pARTS lISTS CDV Series Gas Fireplace FIREBOx COMpONENTS (CDVT Series) (CDVR Series) 69D0023...
  • Page 47: Illustrated Parts Lists

    IlluSTRATED pARTS lISTS CDV Series Gas Fireplace FIREBOx COMpONENTS Item Description Qty. CDVR33 CDVR33 CDVR36 CDVT36 CDVR42 CDVT42 CDVR47 CDVT47 Standard Features Junction Box Assembly 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K 26D2128K Black Louver 54D0246 54D0246 26D0695 26D0695 26D0697...
  • Page 48: Standing Pilot - Millivolt Control Engine

    IlluSTRATED pARTS lISTS CDV Series Gas Fireplace STANDING PIloT — MIllIVolT CoNTRol 11,12,13, 14 69D0023...
  • Page 49 IlluSTRATED pARTS lISTS CDV Series Gas Fireplace STANDING pIlOT – MIllIVOlT CONTROl Item Description Qty. CDV33NV CDV33PV CDV36NV CDV36PV CDV42NV CDV42PV CDV47NV CDV47PV Gas Valve Assy. 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019 Replacement...
  • Page 50: Electronic Ignition Engine

    IlluSTRATED pARTS lISTS CDV Series Gas Fireplace ElECTRONIC IGNITION Item Description Qty. CDV33Ne CDV33Pe CDV36Ne CDV36Pe Gas Valve Assy. 37D0016 37D0017 37D0016 37D00173 Pilot Assembly 37D0020 37D0021 37D0020 37D0021 Burner Tube 54D0288 54D0288 69D0034 69D0034 Flexhose with Shut-off Valve 69D0030 69D0030 69D0030 69D0030...
  • Page 51: Logs

    IlluSTRATED pARTS lISTS CDV Series Gas Fireplace lOGS Item Description CDVR33/CDVT33 CDVR36/CDVT36 CDVR42/CDVT42 CDVR47/CDVT47 Rear Log 54D0121 54D0181 54D0339 54D0339 Right Log 54D0147 54D0116 54D0361 54D0361 Left Log 54D0146 54D0115 54D0360 54D0360 69D0023...
  • Page 52: Vent Components

    IlluSTRATED pARTS lIST CDV Series Gas Fireplace VENT COMpONENTS Current Simpson Simpson Duravent Duravent Qty./ or MHSC or MHSC Selkirk Item Box Description Part no. Part no. Part no. Side wall Flexible Pipe Termination Kit BHSFTKA BHSFTK Includes termination cap with built-in vinyl siding standoff, heat deflector, firestop, 20"...
  • Page 53: Massachusetts Requirements

    Massachusetts Residents only — Please read and follow these special requirements 2. Approved Carbon Monoxide Detectors. Each carbon NOTE REGARDING VENTED pRODuCTS monoxide detector as required in accordance with the above This product must be installed by a licensed plumber or gas fitter provisions shall comply with NFPA 720 and be ANSI/UL 2034 when installed within the Commonwealth of Massachusetts.
  • Page 54 CDV Series Gas Fireplace 69D0023...
  • Page 55: Warranty

    This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. MHSC does not assume for it any other obligations or liabilities in con- nection with sale or use of the appliance.
  • Page 56 CDVR33NV 62.6 CDVR33PV 64.3 CDVT33NV 45.9 CDVT33PV 53.0 CDVR36NV 47.7 CDVR36PV 53.6 CDVR42NV 66.8 CDVR42PV 68.7 CDVT42NV 56.3 CDVT42PV 64.3 CDVR47NV 65.6 CDVR47PV 67.1 CDVT47NV 54.2 CDVT47PV 62.4 MhSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com jANuARy 2009 P/N 69D0023 • Rev. 8...

This manual is also suitable for:

Cdvt33Cdvr36Cdvt36Cdvr42Cdvt42Cdvr47 ... Show all