Release Timer For Virtual Tie Lines (Home-Side And Mate-Side Trunks) - Philips SOPHO 2000 IPS User Manual

Hide thumbs Also See for SOPHO 2000 IPS:
Table of Contents

Advertisement

Release Timer for Virtual Tie Lines (Home-Side and Mate-Side Trunks)

START
CM41
Specify the release timer for voice channels of
virtual tie line. If there are no calls for prede-
termined time, the voice channels used for
Event Based CCIS is released.
Specify the release timer for CCH channel of
virtual tie line. If all the voice channels are re-
leased and there are no calls for predetermined
time, the CCH channel used for Event Based
CCIS is released.
END
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
Y=0
(1)
87: Virtual Tie Line Release Timer
for Voice Channels
(2)
02: 2.4-4.8 seconds
(2.4 second increments)
30: 69.6-72.0 seconds
32: 24 seconds
(24 second increments)
70: 936 seconds
72: 1 minute
(1 minute increments)
99: 28 minutes
NONE : 3 minutes
(Error span: 2.4 seconds)
Y=0
(1)
89: Virtual Tie Line Release Timer
for Common Signaling Channel
(2)
02: 2.4-4.8 seconds
(2.4 second increments)
30: 69.6-72.0 seconds
32: 24 seconds
(24 second increments)
70: 936 seconds
72: 1 minute
(1 minute increments)
99: 28 minutes
NONE : 3 minutes
(Error span: 2.4 seconds)
– 205 –
EVENT BASED CCIS PROGRAMMING
DATA
NWA-008852-001 Rev.5.0
98ch3002.fm