Panasonic KX-HCM10 Operating Instructions Manual page 67

Network camera
Hide thumbs Also See for KX-HCM10:
Table of Contents

Advertisement

Instructions for the data fields
a.
External Sensor Input of External I/O activates the alarm trigger.
Please refer to Section 4.2 Interfacing to the External I/O.
b.
Active Time of Trigger
The active trigger time can be set in the primary time and the secondary
time. The secondary time is the supplement of the primary time.
Always: always activates the alarm trigger.
Operational between: Sets the starting and stopping time of the
primary time. The day of the week can be set by checking.
Starting and stopping time is set only in 24 h time mode.
Alarm enable condition:
Please select the [Rising] (GND to Open High) or [Falling] (Open High
to GND) of External Sensor Input of the External I/O.
c.
Secondary time is active trigger time except the primary time.
Alarm enable condition:
Please select the [Rising] (GND to Open High) or [Falling] (Open High
to GND) of External Sensor Input of the External I/O.
d.
Sets the image resolution and image quality.
Image resolution: 640 x 480/320 x 240/160 x 120
Image quality: Favour Clarity/Standard/Favour Motion
e.
The Pre and/or Post trigger can be set on the Buffered Image. Please
check the box.
f.
Image Frequency: Sets the interval to send the image.
Maximum number of images per each trigger:
Selects the number of buffering frames from numbers 1 to 400.