11. Do not run fireplace insert
• where flammable liquids or vapors are used or stored
• under dusty conditions.
12. Do not use this fireplace insert to cook food or burn paper or other
objects.
13. Do not use fireplace insert if any part has been exposed to or under
water. Immediately call a qualified service technician to inspect
fireplace insert and to replace any part of the control system and
any gas control which has been under water.
14. Do not operate fireplace insert if any log is broken. Do not operate
fireplace insert if a log is chipped (dime-sized or larger).
15. Turn fireplace insert off and let cool before servicing. Only a quali-
fied service person should service and repair fireplace insert.
16. Operating fireplace insert above elevations of 4,500 feet could
cause pilot outage.
17. To prevent performance problems with propane/LP units, do not
use propane/LP fuel tanks of less than 100 lb. capacity (propane/
LP units only).
Install and use fireplace insert with care. Follow all local codes. In
the absence of local codes, use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CAUTION: Do not remove the warning and instruc-
tion labels attached to the heater base assembly.
These markings contain important warranty and safety
information.
1.
With utility knife, cut carton all the way around above staples on
bottom tray. Lift carton off of heater. Remove packing.
Note: Hood is located in packing on right hand side of heater
front. Lift heater off bottom tray.
4
SAFETY Continued
18. Provide adequate clearances around air openings.
19. Trim panels and surrounds must not seal ventilation openings in
fireplace.
20. Cutting any sheet metal parts of the solid-fuel burning fireplace or
listed ventless firebox enclosure in which the vent-free fireplace
insert is to be installed is prohibited.
21. If factory-built fireplace has no gas access hole(s) provided, an
access hole of 1.5" (37.5 mm) diameter or less may be drilled
through the lower sides or bottom of firebox in a proper manner.
This access hole must be plugged with noncombustible insulation
after the gas supply line has been installed.
22. Refractory, glass doors, screen rails, screen mesh and solid-fuel
log grates (if applicable) can be removed from the fireplace before
installing the unvented fireplace insert.
23. Smoke shelves, shields and baffles may be removed if attached
by mechanical fasteners.

LOCAL CODES

State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of Massa-
chusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom
installation in the Commonwealth of Massachusetts.

UNPACKING

2.
Locate two screws above top corners of fireplace insert screen.
Remove and discard these screws. Lift fireplace insert screen
up and pull out to remove.
3.
Remove protective packaging applied to logs, log base assembly
and fireplace insert.
4.
Remove fireplace insert hood from carton insert.
5.
Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought fireplace insert.