Superior VRT43STWS Installation And Operation Instructions Manual

Unvented (vent-free) universal firebox

Advertisement

Quick Links

P/N 126703-01 Rev.A 02/2014
P126703-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Superior
PFS
Models
®
US
Unvented (Vent-Free) Universal Firebox
TM
VRT43STWS
VCT43STWS

Advertisement

Table of Contents
loading

Summary of Contents for Superior VRT43STWS

  • Page 1 Superior Unvented (Vent-Free) Universal Firebox P/N 126703-01 Rev.A 02/2014 Models ® VRT43STWS VCT43STWS P126703-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. TABLE OF CONTENTS Safety ..............
  • Page 3 SAFETY Continued 1. This firebox shall not be installed in a Due to high temperatures, the bedroom or bathroom. appliance should be located out 2. Never install the firebox of traffic and away from furniture • in a recreational vehicle and draperies.
  • Page 4: Local Codes

    LOCAL CODES Install and use firebox with care. Follow all State of Massachusetts: The installation local codes. In the absence of local codes, must be made by a licensed plumber or use the latest edition of The National Fuel Gas gas fitter in the Commonwealth of Mas- Code ANS Z223.1/NFPA 54*.
  • Page 5: Product Specifications

    PRODUCT SPECIFICATIONS " 24" 1/2" 5/8" " " 3" " " 4" " " 40" " " " " " 12" Figure 1 - Dual-Sided Firebox LOCATING FIREBOX PLANNING Internal wall installation provides a discreet viewing option between two Plan where you will install the firebox. This will adjacent rooms or within an added wall save time and money later when you install to subdivide an oversize room.
  • Page 6: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Unusually Tight Construction WARNING: This appliance The air that leaks around doors and windows shall not be installed in a room may provide enough fresh air for combustion or space unless the required and ventilation. However, in buildings of un- usually tight construction, you must provide volume of indoor combustion additional fresh air.
  • Page 7: Combustion And Ventilation Air

    AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ FOR FIREBOX LOCATION Hr used. Determining if You Have a Confined or _______ Btu/Hr (maximum the space can Unconfined Space support) Use this work sheet to determine if you have...
  • Page 8: Installation

    AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation Ventilation Air From Inside Building grills or ducts. You must provide two perma- This fresh air would come from an adjoining nent openings: one within 12"...
  • Page 9 INSTALLATION Continued C. When firebox is installed on carpeting CAUTION: Log appliances or other combustible material, other installed in this firebox create than wood flooring, the firebox should be installed on a metal or wood panel warm air currents. These currents extending the full width and depth of the move heat to wall surfaces next enclosure.
  • Page 10 INSTALLATION the clearances shown in Figure 7. Follow the instructions below to install the firebox in this Continued manner. Mantel Clearances for Built-In 1. Frame in rough opening. The firebox Installation framing should be constructed of 2 x 4 If placing custom mantel above built-in fire- lumber or heavier.
  • Page 11 INSTALLATION WARNING: Framing may be Continued placed or rest against fireplace flange (see Figure 10). spacer, however; framing must 8. If using optional brass trim kit, install the never be notched. trim after final finishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.
  • Page 12 INSTALLATION Continued hand sides (see Figure 11). Remove the gas CAUTION: Do not use exces- line cover plate from the vent-free firebox’s sive force to remove the knock- outer surround at the location to be used. out. Too much force may damage If a sediment trap is not incorporated as a part of the gas utilization equipment, one shall be the firebrick concrete insert.
  • Page 13 INSTALLATION Continued HARD-WIRING FIREBOX Prepare incoming black iron gas line with Teflon tape or pipe joint compound (check with This model only can be hard-wired to the local codes as to the use of Teflon tape). Com- duplex outlet located inside the firebox bottom pounds used on threaded joints of gas piping if desired.
  • Page 14 INSTALLATION Continued 5. Apply gentle force between hook and loop to the receptacle must be provided for use mounting strips to seat blower. with the optional blower kit whether installed 6. Remove control knob and lock nut from during or after initial firebox installation. You blower speed control shaft.
  • Page 15 INSTALLATION Continued FIELD WIRE INCOMING 120V AC BLOWER (FUSE BOX RECEPTACLE BREAKER) VARIABLE ELECTRICAL RATING: SPEED CONNECTORS 120v, 60Hz, 0.9A CONTROL (NOT SUPPLIED) Note: If any of the original wire must be replaced, it must be replaced with type TEW minimum 16GA copper wire rated at 105°C Figure 17 - Optional Blower Wiring Diagram HEAT DEFLECTIVE HOOD Front Hood...
  • Page 16: Operating Guidelines And Maintenance Instructions

    OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, a vent-free log appli- Installation and repair should be done by a ance will emit a slight odor for about an hour qualified person. The appliance should be or two. This is a normal occurrence which is inspected before use and at least annually by due to the “curing”...
  • Page 17: Technical Service

    TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact INNOVATIVE HEARTH PRODUCTS at 1-800-655-2008. When calling please have your model and serial numbers of your appliance ready. You can also visit the INNOVATIVE HEARTH PRODUCTS web site at www.IHP.US.com. ACCESSORY Purchase these accessories from your local dealer.
  • Page 18: Parts

    PARTS MODELS VCT43STWS AND VRT43STWS 17** 10** 16** 16** 16** 11** 16** 16** 16** 16** 16** **These items are used on both sides of fireplace. www.SuperiorFireplaces.US.com 126703-01A...
  • Page 19 PARTS MODELS VCT43STWS AND VRT43STWS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 16 of this manual. NO. PART NO. DESCRIPTION QTY. Firebox Assembly • • Firebox Bottom •...
  • Page 20: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 21 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.SuperiorFireplaces.US.com 126703-01A...
  • Page 22 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126703-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126703-01...