Equipment
Shutoff
Valve
Figure 17 - Equipment Shutoff Valve
Manual Gas Valve
Figure 18 - Checking Gas Joints (Natural Gas)
Equipment Shutoff Valve
Manual Gas Valve
Figure 19 - Checking Gas Joints (Propane/LP Gas)
PRESSURE TESTING FIREPLACE INSERT GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 17).
2. Open main gas valve located on or near gas meter for natural gas
or open propane/LP supply tank valve.
3. Make sure control knob of fireplace insert is in the OFF position.
4. Check all joints from gas meter to equipment shutoff valve for
natural gas (see Figure 18) or propane/LP supply to equipment
shutoff valve for propane/LP (see Figure 19). Apply a noncorrosive
leak detection fluid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace insert (see Operation, page 16). Check all other
internal joints for leaks.
7. Turn off fireplace insert (see To Turn Off Gas to Appliance, page
17).
127119-01A
INSTALLATION Continued
Open
FIREPLACE INSERT INSTALLATION INTO MASONRY FIREPLACE
Installation of this fireplace insert involves installing fireplace insert
into wood burning fireplace. If using a mantel above the fireplace,
you must follow the clearances shown in Figure 12, page 10. Follow
instructions below to install fireplace insert in this manner.
1. Use dimensions shown in Figure 20 for masonry fireplace opening.
Closed
2. Install and properly ground GA3555, three-prong 120 volt electrical
outlet, in fireplace insert. Follow instructions included in kit (see
Accessories, page 28).
3. Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
Equipment
equipment shutoff valve. Flexible gas line must be the last item
Shutoff
installed on gas piping. See Installing Gas Piping to Fireplace
Valve
Location, page 11.
4. Carefully set fireplace insert in front of masonry fireplace with
Gas
back of insert inside opening.
Meter
5. Attach flexible gas line to gas supply. See Connecting Fireplace
Insert to Gas Supply, page 12.
6. Plug electrical cord into electrical outlet installed in step 2.
7. Carefully place fireplace insert into masonry fireplace.
8. Check all gas connections for leaks. See Checking Gas Connec-
tions, page 12.
9. Install trim after final finishing and/or painting of wall (see Figure
22, page 14).
ASSEMBLING AND ATTACHING TRIM
Propane/
LP Supply
Tank
Figure 20 - Rough Opening for Installing in Masonry Fireplace
www.Superiorfireplaces.US.com
Insert
Height
25
/
"
9
16
Front Width
34
/
"
5
16
Depth
16
/
"
11
16
17
26
1
/
"
4
35"
Minimum Fireplace
Opening
26
/
"
1
4
35"
17
/
"
1
4
1
/
"
4
13

Advertisement