Oki OKIPAGE 12i Service Handbook page 108

Digital led printer
Hide thumbs Also See for OKIPAGE 12i:
Table of Contents

Advertisement

• Yes
1-1
• Take the measurement of the following voltage readings at connector CN2 on the power
supply/sensor board:
Voltage between Pins 1 and 3: ... about
Voltage between Pins 5 and 6: ... about 9.2 V AC
Are the voltages within the normal range?
• Yes Is fuse F3 on the power supply/sensor board blown?
• Yes Replace fuse F3 (if it blows again, check the resistance of the registration and
• No
• Yes Replace the AC transformer.
• No
• No Replace the power supply/sensor board.
• Yes
ACIN
F1
L
FG
N
Fuse Ratings
AC Input
120 V
Fuse
F1
125 V 6.3 A
F2
125 V 1.6 A
F3
125 V 3.15A
End
• No
Replace the power supply/sensor board.
main/drum motors. If it is faulty, replace motors or replace the power supply/
sensor board or main control board).
Is the AC input voltage output between Pins 1 and 2 of connector CN1 on the
power supply/sensor board normal?
Is fuse F1 or F2 on the power supply/sensor board blown?
Replace blown fuse F1 or F2 (if is blows again, replace the power supply/sensor
board).
Power supply/sensor board
CN1
F2
1
Filter
Circuit
2
230 V
250 V
5 A
250 V 2.5A
Figure 6-1 Low-voltage Power Supply Block Diagram
40 V AC
CN2
F3
Thermal Fuse
1, 2
3, 4
6
5
AC Transformer
6 - 16
+30 V
+30 V
Smoothing
Circuit
+5 V
+5 V
0 V
Stabilizing
Circuit
+8 V
±8 Rectifying/
Smooting
-8 V
Circuit
CN3
17, 18
12
9, 15, 16
24
22