Technical Specifications

Input Voltage
400V  15%
Three Phase
Duty Cycle
(Based on a 10 min. period)
100% (Stick)
100% (TIG)
300TPX
40% (Stick)
40% (TIG)
100% (Stick)
100% (TIG)
400TPX
35% (Stick)
35% (TIG)
Welding Current Range
300TPX
5 – 270A (Stick) / 5 – 300A (TIG)
400TPX
Fuse (delayed) or Circuit Breaker ("D" characteristic) Size
300TPX
400TPX
Height
300TPX
389mm
400TPX
455mm
Operating Temperature
-10°C to +40°C

WEEE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)
and its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility. As the
owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will protect the environment and human health!

Spare Parts

Part List reading instructions
Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service
Department for any code number not listed.
Use the illustration of assembly page and the table below to determine where the part is located for your particular
code machine.
Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate
a change in this printing).
First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that
contains a picture-descriptive part number cross-reference.
English
INPUT
Input Power at Rated Output
6.5kW @ 100% Duty Cycle (Stick)
5.1kW @ 100% Duty Cycle (TIG)
300TPX
9.8kW @ 40% Duty Cycle (Stick)
8.1kW @ 40% Duty Cycle (TIG)
10.8kW @ 100% Duty Cycle (Stick)
7.6kW @ 100% Duty Cycle (TIG)
400TPX
16.4kW @ 35% Duty Cycle (Stick)
11.9kW @ 35% Duty Cycle (TIG)
RATED OUTPUT AT 40°C
Output Current
200A
220A
270A
300A
300A
300A
400A
400A
OUTPUT RANGE
5 – 400A
RECOMMENDED INPUT CABLE AND FUSE SIZES
20A
30A
PHYSICAL DIMENSIONS
Width
247mm
301mm
Maximum Open Circuit Voltage
65Vdc (CE model)
12Vdc (AUSTRALIA model)
Input Power Cable
Length
502mm
632mm
Storage Temperature
-25°C to +55°C
15
EMC Class
A
Frequency
50/60Hz
A
Output Voltage
28.0Vdc
18.8Vdc
30.8Vdc
22.0Vdc
32.0Vdc
22.0Vdc
36.0Vdc
26.0Vdc
2
4x2.5mm
2
4x4mm
Weight
21kg
35kg
07/06
12/05
English