5. MANUAL MODE
This is mode to adjust or check the operation of the set by function.
Operation of The Manual Mode
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to activate the Manual mode where the
LCD displays as shown below.
Display of the remote commander
000 Manual
Number of 1000th place
(000 to 009)
3. During Manual mode, the optical pick-up moves outward or
inward while the
>
seconds respectively.
4. Each test item is assigned with a four-digit item number; 1000th
place is a top item, 100th place is a major item, 10th place is a
medium item, and unit place is a minor item.
Flow of manual mode operation:
[VOL +] key: 1000th place of item
Top item switching
[VOL --] key: 1000th place of item
> key
x key
[VOL +] key: 100th place of item
Major item switching
[VOL --] key: 100th place of item
> key
x key
[VOL +] key: 10th place of item
Medium item switching
[VOL --] key: 10th place of item
> key
x key
> key:
Minor item switching
. key:
Adjusted value variation
[VOL +] key: Increases the adjusted
[VOL --] key: Decreases the adjusted
Adjusted value write
[ +],
Set
Remote commander
Adjusted value is written.
14
or
key is pressed for several
.
number increase.
number decrease.
number increase.
number decrease.
number increase.
number decrease.
1st place of item
number increase.
1st place of item
number decrease.
value.
value.
[
ENT]
u
key:
[ --]
key:
5. The display changes a shown below each time the
[DISPLAY] key is pressed.
• Item Title Display
Remote commander LCD display
XXX * * * * * * # #
item number
• Address & Adjusted Value Display
Remote commander LCD display
XXX * * * S # #
item number
• Jitter Value & Adjusted Value Display
Remote commander LCD display
XXX * * * J # #
item number
• Block/Bite Error Value & Adjusted Value Display
Remote commander LCD display
XXX * * * B # #
item number
• Bite Error LPF Value & Adjusted Value Display *1)
Remote commander LCD display
XXX * * * L # #
item number
• CEMAX Value & Adjusted Value Display *1)
Remote commander LCD display
XXX * * * C # #
item number
• ADIP Error Value & Adjusted Value Display
Remote commander LCD display
XXX * * * A # #
item number
• Focus Drive Value & Adjusted Value Display
Remote commander LCD display
XXX * * * F # #
item number
*1) It is skipped excluding the item number 5000 less than 8000.
6. To release the Manual mode, press the
Display Check mode.
adjusted value
item title
adjusted value
address
adjusted value
jitter value
adjusted value
block/bite error value
adjusted value
bite error LPF value
adjusted value
CEMAX value
adjusted value
ADIP error value
adjusted value
focus drive voltage value
key to return to the