7. Installation details 
7.1    Wrench torque sheet for installation 
 
7.2    Connecting the cables 
The power cord of connect should be selected according to the following specifications sheet. 
Unit 
mm
 
Communication wire between the indoor and outdoor unit: 
Unit 
mm
 
7.3    Pipe length and the elevation 
Pipe size 
Model 
Gas 
FSIArt‐100HFD  3/8'' (Ф9.52) 
FSIArt‐180HFD  1/2'' (Ф12.7) 
 
Caution: 
Capacity is based on standard length and maximum allowance length is base of reliability. 
Oil trap should be installed per 5‐8 meters, (but not definitely needed). 
11 
 
Outside diameter 
mm 
inch 
Ф6.35 
1/4 
Ф9.52 
3/8 
Ф12.7 
1/2 
2
 
2
 
Liquid 
1/4'' (Ф6.35) 
1/4'' (Ф6.35) 
Torque 
Kgf.m 
1.8 
4.2 
5.5 
FSIArt‐100HFD 
3x1,5 
FSIArt‐100HFD 
4x1,5 
Standard 
Max. 
length 
Elevation 
(m) 
B (m) 
10 
FSIArt‐180HFD 
3x2,5 
FSIArt‐180HFD 
4x2,5 
Max. 
Length 
A (m) 
20 
25 
Additional 
refrigerant 
(g/m) 
30 
30 
 