7. Installation details
7.1 Wrench torque sheet for installation
7.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Unit
mm
Communication wire between the indoor and outdoor unit:
Unit
mm
7.3 Pipe length and the elevation
Pipe size
Model
Gas
FSIArt‐100HFD 3/8'' (Ф9.52)
FSIArt‐180HFD 1/2'' (Ф12.7)
Caution:
Capacity is based on standard length and maximum allowance length is base of reliability.
Oil trap should be installed per 5‐8 meters, (but not definitely needed).
11
Outside diameter
mm
inch
Ф6.35
1/4
Ф9.52
3/8
Ф12.7
1/2
2
2
Liquid
1/4'' (Ф6.35)
1/4'' (Ф6.35)
Torque
Kgf.m
1.8
4.2
5.5
FSIArt‐100HFD
3x1,5
FSIArt‐100HFD
4x1,5
Standard
Max.
length
Elevation
(m)
B (m)
5
8
5
10
FSIArt‐180HFD
3x2,5
FSIArt‐180HFD
4x2,5
Max.
Length
A (m)
20
25
Additional
refrigerant
(g/m)
30
30