Sony MDS-PC2 Service Manual page 23

Minidisc deck
Hide thumbs Also See for MDS-PC2:
Table of Contents

Advertisement

5-6. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to
"approximate specifications" to determine the faulty locations. For
details, refer to "Checks Prior to Parts Replacement and
Adjustments" (See page 8).
5-6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room
temperature to 22 to 28°C.
Checking Procedure:
1. Press the + button to display "TEMP CHECK".
2. Press the ^ "PROGRAM" button.
3. "T=@@(##) [OK]" should be displayed. If "T=@@ (##) [NG]"
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
5-6-2. Laser Power Check
Before checking, check the IOP value of the optical pick-up.
(Refer to 5-8. Recording and Displaying IOP Information.)
Connection :
Optical pick-up
objective lens
BD board
CN110 pin 5 (I+3V)
CN110 pin 4 (IOP)
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the = "PRO-
GRAM" button or + "PROGRAM" button to move the
optical pick-up.)
Connect the digital volt meter to CN110 pin 5 (I+3V) and
CN110 pin 4 (IOP).
2. Then, press the + button and display "LDPWR CHECK" .
3. Press the ^ "PROGRAM" button once and display "0.9
mW*** $
". Check that the reading of the laser power meter
become 0.84 to 0.92 mW. (*** means IOP value)
4. Press the ^ "PROGRAM" button once more and display
"7.0 mW*** $
". Check that the reading the laser power meter
and digital volt meter satisfy the specified value.
Specified Value :
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
(For details of the method for checking
KMS
260A
this value, refer to "5-8. Recording and
27X40
Displaying IOP Information".)
B0825
Iop = 82.5 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 ( Ω )
5. Press the p "PROGRAM" button and display "LDPWR
CHECK" and stop the laser emission.
(The p "PROGRAM" button is effective at all times to stop
the laser emission.)
Laser power
meter
Digital volt meter
Note 1: After step 4, each time the ^ "PROGRAM" button is
pressed, the display will be switched between "0.7 mW***
$
", "6.2 mW*** $
Nothing needs to be performed here.
5-6-3. Traverse Check
Connection :
BD board
CN110 pin 3 (TE)
CN110 pin 1 (VC)
Checking Procedure:
1. Connect an oscilloscope to CN110 pin 3 (TE) and CN110 pin
1 (VC) of the BD board.
2. Load a disc (any available on the market). (Refer to Note 1.)
3. Press the + "PROGRAM" button and move the optical pick-
up outside the pit.
4. Press the + button and display "EF MO CHECK".
5. Press the ^ "PROGRAM" button and display "EFB =
MO-R".
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the = , + but-
tons.
(Read power traverse checking)
(Traverse Waveform)
VC
Specified value : Below 10% offset value
I A – B I
Offset value (%) =
2 (A + B)
7. Press the ^ "PROGRAM" button and display "EFB =
MO-W".
8. Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the = , + but-
tons..
(Write power traverse checking)
(Traverse Waveform)
VC
Specified value : Below 10% offset value
I A – B I
Offset value (%) =
2 (A + B)
9. Press the ^ "PROGRAM" button display "EFB =
P".
Then, the optical pick-up moves to the pit area automatically
and servo is imposed.
", and "WP
*** $
Oscilloscope
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
X 100
X 100
".
A
B
A
B
MO-
23

Advertisement

Table of Contents
loading

Table of Contents