4-7. SOUND SKIP CHECK RESULT DISPLAY MODE
This set can display and check the error count occurring during
play.
• Setting method of Sound Skip Check Result Display Mode
1. Setting the test mode.
2. Turn the control towards > N activates the sound skip
check result display mode where the LCD displays as shown
below.
LCD display
000 P**P##
Total of play system
error count
Total of record system error count
3. When > N is turned the control towards, the total of error
count is displayed on the LCD, and each time the > N is
turned the control towards, the error count descents one by one
as shown below. Also, when . is turned the control to-
wards, the error count ascends by one.
000 P**R00
000 EIB **
000 Stat**
000 Adrs**
000 BEmp**
000 ######
P ** R00 : Total of play system error and record system error count
** : Sound skip check items counter (hexadecimal)
##### : 6-digit address (hexadecimal) where a sound skipped
Error code
Cause of error
Playback
EIB
Stat
Adrs
BEmp
4. Quit the sound skip check result display mode, and press the x
key to return to the test mode. (display check mode)
Description of error
Sound error correction error
Decorder status error
Cannot access the address
Buffer becomes empty
4-8. KEY CHECK MODE
4-8-1. Outline of the function
This mode is used to check to make sure that each of the keys
(including the slide switch) on the set operates normally.
4-8-2. Setting the Key Check mode
1. Set the TEST MODE. Press and hold down DISPLAY key (for
more than 3 sec) to set the Key Check mode.
LCD display
000
2. When each key on the set and on remote control is pressed, its
name is displayed on the LCD. (The operated position is dis-
played for 4 sec after the slide switch is operated. If any other
key is pressed during this display, the LCD switches to its name
display)
Example: When > N key on the set is pressed:
LCD display
000 FF
Example: When > N on the remote control is turned the
control towards:
LCD display
000 rPLAY
XX: AD value of the remote control key (hexadecimal 00 to FF)
3. When all the keys on the set and on the remote control are con-
sidered as OK, the following displays are shown for 2 sec.
(The key pressed to enter the Key Check mode has been checked
even if it is not pressed in this mode)
Example: When the keys on the set are considered as OK:
LCD display
888 SET OK OF
Example: When the keys on the remote control are considered
as OK:
LCD display
888 RMC OK OX
4. When all the key have been checked or when the top panel is
opened during this checking, the system terminates the Key
Check mode and return to the TEST MODE.
MZ-E505
0F
0F
XX
17