The illustrations below provide the overall
dimensions, countertop cut-out and installation
specifications for Model ICBCT15G/S.
For Model ICBCT15G/S, the gas service may be
supplied through the floor if the cooktop is not
installed above an oven. Refer to the illustration
for specifics on placement of gas and electrical.
I N S T A L L A T I O N S P E C I F I C A T I O N S – M O D E L I C B C T 1 5 G / S
533 mm
533 mm
OVERALL
OVERALL
DEPTH
DEPTH
381 mm
381 mm
OVERALL
OVERALL WIDTH
WIDTH
102 mm
102 mm

Overall Dimensions

M O D E L I C B C T 1 5 G / S
D I M E N S I O N S
Overall Width
Overall Height
Overall Depth
Recommended
Cabinet Width
Minimum Cabinet Depth
Minimum Height Clearance 102 mm
Cut-Out Width
Cut-Out Depth
Unit dimensions may vary to ± 3 mm.
6
G A S C O O K T O P S
S P E C I F I C A T I O N S
330 mm
max
64**
489 mm
mm
COOKTOP CUT-OUT
DEPTH
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 127 mm ON
FLOOR FROM BACK WALL
381 mm
127
mm
102 mm
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
533 mm
recommended cabinet width for installation of single 381 mm cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
838 mm
578 mm
Countertop Cut-Out
356 mm
489 mm
Note A:
Side clearances. If the distance
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
clauses 5.12.1.1. & 5.12.1.2 of AS5601.
IMPORTANT NOTE: When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
178 mm*
min
457 mm
CUT-OUT TO
COMBUSTIBLE
COOKTOP CUT-OUT
Note A
64 mm
MATERIALS
min
(BOTH SIDES)
E
914 mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
LOCATION OF GAS SUPPLY
MAY ALSO EXTEND 127 mm ON
FLOOR FROM BACK WALL
COOKTOP CUT-OUT
64 mm
min
Note B:
The rangehood fitted above the
cooktop must be installed according
to the installation instructions for
the rangehood. A minimum
distance of 750 mm is required for a
range hood and 750 mm for an
exhaust fan
838 mm
RECOMMENDED
762 mm
CABINET WIDTH
COUNTERTOP TO
Note B
356 mm
COMBUSTIBLE
MATERIALS
WIDTH
ABOVE COOKTOP
102 mm
G
381
mm
381 mm
381 mm
356 mm
WIDTH
489 mm
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
.