Power supply units
6.4.3
Installing the new hot-plug power supply unit
Figure 16: Installing the hot-plug power supply unit
Ê Push the power supply unit into its slot (1) as far as it will go until the locking
latch snaps in place (2).
V
CAUTION!
Ensure that the power supply unit properly engages in its slot and is
locked in position in order to prevent it from sliding out of the chassis
during transportation.
Ê If applicable, fold down the handle on the power supply unit (3).
6.4.4
Concluding steps
"Connecting the server to the power source" on page 55
Ê
Ê In non-redundant PSU configurations, switch on the server as described in
section
"Switching on the server" on page 56
"Performing a fan test after replacing a defective fan" on page 86
Ê
"Enabling BitLocker functionality" on page 80
Ê
98
Upgrade and Maintenance Manual
RX4770 M1