Panel Link Specifications - Teledyne BOA Pro Installation Manual

Smart vision system
Table of Contents

Advertisement

Panel Link Specifications

The PL-100 module offers additional isolation for the BOA camera and simplifies wiring
at the control panel. The module also provides power over Ethernet for single cable
applications.
I/O connections to the BOA camera should be wired to the TOP connectors on the PL-
100 (J2 and J3) directly.
so may make the PoE feature unusable. In this case power must always be supplied
through the IO cable.
I/O connections in the control panel (outside word) should be wired to the BOTTOM
connectors on the PL-100 (J5 and J6). Specification for these signals are as follows:
Specification
Voltage
Current
Protection
Common
Switch Time
PL-100 Connections
Ethernet
connection to BOA
Manual Trigger for
debugging
Ethernet
connection to PC
Version 02
NOTE: Avoid reversing PWR/GND on the I/O connector. Doing
Definition
Load
24V maximum
GPO[0:1]
100mA max
Fuse
PTC fuses to 100mA (GPO)
ICMN/OCMN
PWR or GND as wired on respective OPTOs
GPO[0:1]
100 Microsecond (ON or OFF)
teledynedalsa.com/ipd
I/O connections to
BOA (A-BVS-IO8)
I/O connections to
control panel
23