INSTALLATION

Wiring Connections

INTERNAL BLOWER WIRING
Remove the top cover of the electrical box by extracting
1
two screws. Refer to the illustration below.
Remove the two existing wires from the left side of the
2
terminal block, then transition them to the right and
secure. Refer to the illustration below.
Place all wiring connections inside the electrical box and
3
reinstall the cover. Make sure all wires are secure and not
pinched between the cover and electrical box.
Secure the junction box supplied with the hood to the
4
wall, then connect to the (Romex
the home. Once the connection has been made, insert
the plug into the receptacle on the hood.
COVER
MOVE WIRES
HERE
Wiring location.
®
) power supply from
TO INTERNAL
BLOWER
Internal blower wiring.
IN-LINE / REMOTE BLOWER WIRING
Remove the top cover of the electrical box by extracting
1
two screws. Refer to the illustration below.
Remove one of the round knockouts using a flat blade
2
screwdriver.
®
Insert Romex
wire from the blower through the
3
knockout and secure using an approved cord stain relief.
Connect white to blue, black to brown and green to
4
ground. Refer to the illustration below.
Place all wiring connections inside the electrical box and
5
reinstall the cover. Make sure all wires are secure and not
pinched between the cover and electrical box.
Secure the junction box supplied with the hood to the
6
support frame, then connect to the (Romex
supply from the home. Once the connection has been
made, insert the plug into the receptacle on the hood.
COVER
KNOCKOUT
Wiring location.
®
) power
GROUND
TO IN-LINE / REMOTE
BLOWER
In-line / remote blower wiring.
|