Four winns vista Owner's Manual page 53

Table of Contents

Advertisement

Figure E12: Deep Alarm Setting Value
NOTICE
The minimum DEEP ALARM setting can not
meet or go below the current SHALLOW
ALARM setting.
After your selection is made, the unit will return to nor-
mal operation after 5 seconds. The “DEEP” icon should
now be visible. See Figure E13.
Figure E13: “DEEP” Icon
If the depth of the water is greater than the selected
value, the alarm will sound and the icon will blink to
indicate the alarm. Pressing any button will mute the
alarm; pressing the SET will mute the alarm and acti-
vate the DEEP ALARM function for additional adjust-
ment. To permanently turn off, use the DOWN AR-
ROW to return the display to “OFF”.
4. Units
The UNITS Control Function selects the UNITS of mea-
sure for depth readout and alarm functions. The three
settings available are Feet, Meters or Fathoms. See
Figure E14.
Figure E14: Units Control Function
Press SET until the units function is activated on-screen.
This is indicated by the blinking UNITS icon. Pressing
either arrow will allow you to select from the choices.
Continue to press an arrow until the desired readout is
selected: FT for feet, M for meters, FA for fathoms.
After your selection is made, the unit will return to nor-
mal operation after 5 seconds. The selected units icon
348 Vista Owner’s Manual
08/01
should now be visible as shown in Figure E14.
Figure E14: Selected Units Icon
5. Keel Offset
The Keel Offset function adjusts the digital depth read-
out to display depth reading from either the waterline or
the keel (lowest point) of the boat, instead of from the
location of the transducer which is usually somewhere in
between. This permits optimum transducer location and
depth readouts suited to your needs.
To determine the value to enter into the KEEL OFFSET
setting, first decide whether depth from the waterline or
depth from the keel is desired. Measurements will
need to be made for the location desired.
For depth from the keel of the boat, accurately measure
the vertical distance between the face of the transducer
and the keel of the boat. This measurement will then be
entered into the Keel Offset function as a negative (-)
number. See Figure E16.
Figure E16: Negative Keel Offset
For depth measurements from the waterline, accurately
measure the vertical distance from the face of the trans-
ducer and the waterline of the boat. This measurement
will then be entered into the Keel Offset function as a
positive (+) number. See Figure E17.
Figure E17: Positive Keel Offset
To Enable Keel Offset press SET until the KO icon is
displayed on the screen. The default setting of the unit
is off which is displayed as zero. From the default set-
ting of 0.0, use the DOWN arrow to enter the negative (-
) number to set the unit for depth from the keel. Or, from
the default setting of 0.0, use the UP arrow to enter the
Section E
Page 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

348 vista338 vista