5. SPECIFICATIONS OF ELECTRICAL PARTS

5-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
Transformer
4
Microcomputer
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L02)
Running capacitor
7
(for indoor fan motor)
8
Fuse (F01)
9
Varistor (R01, R02, R03)
10
Drain pump control relay
Type
Output (Rated ) 60W, 4 pole, 1 phase,
220 – 240, 50Hz/220, 60Hz
MF-200-60-4R
Winding resistance (Ω)
at 20°C
( – )
10kΩ at 25°C
TT-03-3
AC 240V, Secondary DC 15V/DC 500mA
TMP87PM40ANG
( – )
10kΩ at 25°C
HF-2430-253Y0R8
25mH, AC 0.8A
CMPS45B155UYF
1.5µF, AC 450V (M10, M13)
CMPS45B305UYF
3.0µF, AC 450V (M16)
TSCR6.3A
T6.3A, AC 250V
15G471K
470V
G2R-1-H
10A, AC 250V
– 10 –
Specifications
M coil
73.8
A coil
100