INSTALLATION INSTRUCTIONS (optional)
Fig.16
Fig.17
1. Install the window Exhaust adaptor B onto the exhaust
2. Push the Exhaust hose into the airoutlet opening along the
The exhaust hose can be installed into the wall
(Not applicable to the units without adaptor A, expansion
Fig.18
1. Prepare a hole in the wall. Install the wall Exhaust adaptor A
Expansion plug
position
Adaptor A
Adaptor
cap
max 120CM
min 30CM
Fig.19
Fig.20

Exhaust hose installation:

The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode.
COOL, AUTO mode
FAN,DEHUMIDIIFY mode
hose as shown in Fig.16. or Fig.17. Refer to the previous
pages for window kit installation.
the arrow direction(See Fig.18).
plugs and wooden screws of Accessories )
.
onto the wall(outside) by using 4 expansion plugs and
wooden screws, be sure to fix thoroughly. (See Fig.19)
2. Attach the Exhaust hose installed adaptor B(round mouth)
to wall Exhaust adaptor A.
Note:
Cover the hole using the adaptor cap when not in use.
The duct can be compressed or extended moderately
according to the installation requirement, but it is
desirable to keep the duct length to a minimum.
IMPORTANT:
DO NOT OVER BEND THE DUCT (SEE Fig.20)
CAUTION:
Make sure that there is no obstacle around the air outlet of
the exhaust hose (in the range of 500mm) in order to the
exhaust system works properly.
12
Install
Remove
Fig.21
Drain plug
Continuous
drain hose
INSTALLATION INSTRUCTIONS

Water drainage:

Remove the
-
During dehumidifying modes, remove the drain
drain plug
plug from the back of the unit, install the drain
connector(5/8 universal female mender) with
3 4 hose(locally purchased). For the models
without drain connector, just attach the drain
hose to the hole. Place the open end of the
hose directly over the drain area in your
basement floor. Please refer to Fig.21 & 22.
-
When the water level of the bottom tray reaches
a predetermined level,
the digital display area shows P1 . At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away (Fig.23). Re-install the bottom
drain plug and Restart the machine until the P1
symbol disappears. If the error repeats, call for
Fig.22
service.
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.
Bottom drain plug
Fig.23
13
the unit beeps 8 times,

Advertisement

Table of Contents
loading