Air Conditioner Features; Electronic Control Operating Instructions; Operating Instructions - Carrier MOBILE TYPE AIR CONDITIONERS Owner's Manual

Mobile type air conditioners (local air conditioners)
Table of Contents

Advertisement

AIR CONDITIONER FEATURES

ELECTRONIC CONTROL OPERATING INSTRUCTIONS

Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbol for the functions you desire.
The unit can be controlled by the unit control panel alone or with the remote controller .
NOTE: This manual does not include Remote Controller Operations, see the <<Remote
Controller Instruction>> packed with the unit for details.
OPERATION PANEL OF THE AIR CONDITIONER
7
1
2
3
Fig.3
MODE select button
1
Selects the appropriate operating mode.
Each time you press the button, a mode
is selected in a sequence that goes from
AUTO, COOL, DRY and FAN .The mode
indicator light illuminates under the different
mode setting.
2
SLEEP button
Used to initiate the SLEEP operation.
UP(
) and DOWN(
) button
3
Used to adjust (increasing/decreasing)
temperature settings(1 C/2 F increments)
in a range of 17 C(62 F) to 30 C(88 F) or
the TIMER setting in a range of 0~24hrs.
NOTE: The control is capable of displaying
temperature in degrees Fahrenheit or degrees
Celsius. To convert from one to the other, press
and hold the Up and Down buttons at the same
time, for 3 seconds.
6
5
OFF
ON
3
4
4
ON-OFF button
Power switch on/off.
5
TIMER button
Used to initiate the AUTO ON start time
and AUTO OFF stop time program, in
conjuction with the
&
buttons.
6
FAN button
Press to select the fan speed in three steps-
LOW , HIGH and AUTO. The fan speed
indicator light illuminates under different fan
settings except AUTO speed. When select
AUTO fan speed, all the fan indicator lights
will turn dark.
LED Display
7
-Shows the set temperature in
O
F and the Auto-timer settings.
While on DRY and FAN modes, it shows
the room temperature.
6
Error codes:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2-
Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4-
Display panel communication
Unplug the unit and plug it back in.
If error repeats, call for service.
Protection codes:
P1-
Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.
NOTE: When more than one codes occur,
the priority of the code display order is:
E4--E2--E1--P1.

Operating Instructions

COOL operation
-
Press the "MODE" button until the "COOL"
indicator light comes on.
-
Press the ADJUST buttons " " or "
select your desired room temperature. The
temperature can be set within a range of
O
O
O
17 C-30 C/62 F-88 F.
-
Press the "FAN" button to choose the fan speed.
DRY operation
-
Press the "MODE" button until the
"DRY" indicator light comes on.
-
Under this mode, you cannot select a
fan speed or adjust the temperature.
-
Keep windows and doors closed for
the best dehumidifying effect.
-
Do not put the duct to window.
AUTO operation
-
When you set the air conditioner in
AUTO mode, it will automatically select
cooling, fan only operation depending
on what temperature you have selected
and the room temperature.
-
The air conditioner will control room
temperature automatically round the
temperature point set by you.
-
Under AUTO mode, you can not select
the fan speed.
FAN operation
-
Press the "MODE" button until the
"FAN " indicator light comes on.
O
C
or
-
Press the "FAN" button to choose the
fan speed. The temperature cannot be
adjusted.
-
Do not put the duct to window.
OPERATING INSTRUCTIONS
TIMER operation
-
When the unit is on, first press the
Timer button, the TIMER OFF
indicator light illuminates. It indi-
cates the Auto Stop program is
initiated.Press the Timer button
error-
again,the TIMER ON
illuminates. It indcates the Auto
Start program is initiated.
-
Timer button, the TIMER ON indic-
ator light illuminates. It indicates
the Auto Start program is initiated.
When the unit.Press the Timer button
again,the TIMER OFF indicator light
illuminates. It indcates the Auto
Stop program is initiated.
-
button to change the Auto time by
0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24
hours. The control will count down
the time remaining until start.
-
seconds and the system will autom-
" to
atically revert back to display the
previous temperature setting.
- Turning the unit ON or OFF at any
O
time or adjusting the timer setting
to 0.0 will cancel the Auto Start/
Stop timed program.
-
occurs, the Auto Start/Stop timed
program will also be cancelled.
7
indicator light
When the unit is off, first press the
Press or hold the UP or DOWN
The selected time will register in 5
When the malfunction (E1 or E2)