Remove Ignition Modules - Kohler Courage SV710-740 Service Manual

Vertical crankshaft
Hide thumbs Also See for Courage SV710-740:
Table of Contents

Advertisement

Section 8
Disassembly
1. Remove the mounting screws securing the two
inner baffles to the crankcase. Note the position
of any lifting bracket(s). Remove the inner baffles.
See Figure 8-20.
(# 2) Side
Mounting Screws

Remove Ignition Modules

1. Rotate the flywheel so the magnet is away from
the modules.
2. Disconnect the lead(s) from each ignition module.
Fixed Timing Models and DSAI Models have one
lead per module and DSAM or SMART-SPARK™
(variable timing) ignition modules have two leads
per module. See Figure 8-21.
3. Remove the mounting screws and ignition
modules. Note the position of the ignition
modules.
8.6
Lifting
Strap
Standard (Fixed) Timing Ignition
Module (Single Lead) shown
DSAM or SMART-SPARK™
Ignition Module (Two-Leads)
Figure 8-21. Removing Ignition Modules.
Regulator
1. Remove the four hex flange screws securing
the intake manifold to the cylinder heads. Note
which screws hold the wiring clamp(s).
2. Remove the intake manifold and O-Rings. Leave
the wiring harness attached to the manifold. See
Figure 8-22.
Intake Manifold Mounting
Locations
Figure 8-22. Intake Manifold Mounting Locations.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Courage pro sv810-840

Table of Contents