3.2.19 Platen Assembly

· Perform these procedures:
· Push the release lever (1) to the rear of the printer.
· Pull the platen lock levers (2) in the direction of arrow A.
· Rotate the lock levers in the direction of arrow B. This releases the platen assembly (3) from the chassis.
· Lift and remove the platen assembly.
NOTES:
Installation
Before installation, turn the bias gear (4) towards the front of the printer as far as it will go.
Set the platen assembly into place.
Verify that the bias gear securely engages the line feed motor gear.
Secure the two lock levers.
Set the release lever to OPEN (front) and check that the groove of the paper chute firmly engages with the
groove of the main chassis.
Cleaning
When cleaning, refer to Section 3.4 of this Service Handbook
Lubrication
When lubricating, refer to Section 3.5 of this Service Handbook
Do NOT lubricate the line feed motor gear. Lubricant will cause the gear to disintegrate.
P/N 50061305 Platen: (Assembly) Both 90 RSPL A B C
P/N 50061306 Platen: (Assembly) Both 91 RSPL A B C