After 30 minutes passed, the different value of
room temperature and set temperature is
separated zone again by more different value
than before. Then compressor motor speed
after 30 minute passed is lower than before by
the same different value of room temperature
and set temperature.
(7) COMFORT SLEEP operation control.
When the [COMFORT SLEEP] button is pushed,
the ECONO operation actrvate together with the
timer OFF function. Each time of pressing
[COMFORT SLEEP] button the off timer setting
changes in the sequence of 1, 3, 5 or 9 hours.
(8) Hi POWER operation control.
When the [Hi POWER] button is pushed Hi Power
operation is performed by changing setting
temperature and air flow (display on the remote
control does not change).
1) Changing of setting temperature.
Fig. 6-2-12
Fig. 6-2-11
2) Changing of air flow (Fan setting : AUTO)
When the Hi POWER is started, the fan of the
indoor unit operates at higher air flow level than
normal air flow AUTO (normal air flow AUTO is
shown in Fig. 6-2-8). Because of the difference
between room temperature and setting
temperature are increased automatically.
3) Changing of air flow (Fan setting : One of 5 levels)
When the Hi POWER is started, the fan of the
indoor unit operates at higher consecutive air
flow level. (Fan speed on the display of remote
control does not change)
(9) QUIET operation control.
When the [QUIET] button is pushed, the fan is
restricted the revolution speed at L- level until
the [QUIET] button is pushed once again
(cancel QUIET operation).
Remarks :
QUIET operation is appropriate to work with
less heating load condition. Because of the fan
speed L- may cause not enough the heating
capacity.
− 18 −