Post-Installation Configuration & Checkout

3.2.1.2 ARINC 429 Ports

While on the Ground Maintenance SETUP menu page, press the 429 PORTS line select key to
configure the ARINC 429 ports. The ARINC 429 ports setup page is shown in Figure 3-3.
Push in the Cursor knob to allow editing of the settings. Turn the large, outer knob to select the next or
previous item and the Cursor knob to change currently selected setting. Set each ARINC 429 port
according to the installation, and leave unused ports set to NONE. Either press the Cursor knob in again
or press the MENU/ENTER key to save the settings. Press the SETUP or BACK smart key to return to
the Ground Maintenance SETUP menu. The available ARINC 429 input and output port settings are
shown in Table 3-2, and the definition of each available configuration is found in section 2.8.10.2.
The Source Destination Identifier (SDI) field on the EFIS ARINC 429 input can be configured as SYS 1
or SYS 2 and should be set according to which system (#1 or #2) the GNS 480 is in a particular
installation. However, other inputs (ADC, AHRS) are accepted regardless of the SDI, and are indicated
with ALL in the SDI column (the value of ALL cannot be changed).
The SDI field on the ARINC 429 outputs can be configured as SYS 1, SYS 2, or ALL. For dual GNS 480
installations, each GNS 480 must have a unique source name (SYS 1 or SYS 2). For a single GNS 480
installation, select ALL.
Table 3-2 - ARINC 429 Input and Output Port Settings
Channel
429_IN_1
429_IN_2
High / Low
429_IN_3
429_OUT_1
High / Low
429_OUT_2
High / Low
If GTX33+TIS is set up on an RS232 serial port, the SKYWATCH and SKYWATCH
NO UI options will not be available on the ARINC 429 inputs.
3-4
Figure 3-3 - ARINC 429 Ports Setup Page
Speed
Low
ADC / NONE
AHRS / EFIS / NONE
High
SKYWATCH / SKYWATCH NO UI / NONE
ARINC 429 / GAMA 429 NO FP / VOR/ILS / ARINC 743 / NONE
ARINC 429 / GAMA 429 NO FP / VOR/ILS / ARINC 743 / NONE