Haier AU282AHBEA Service Manual page 291

Hide thumbs Also See for AU282AHBEA:
Table of Contents

Advertisement

Module error
1
No load
2
Overheated
3
compressor
4
Total overcurrent
Fault
in
ambient
5
temperature sensor
Fault
in
heat
6
exchange sensor
ROM of single chip
7
micro-controller
is
broken
Overvoltage
8
protection
Overload in cooling
9
10
E2ROM error
LED1, LED2, LED3 and LED4 for outdoor unit are used to show fault information:
No.
(Fault
Fault name
code)
1
Module error
2
No load
3
Transmission error
4
Overheated
compressor
5
Total overcurrent
6
Fault
in
temperature sensor
7
Fault
in
exchange sensor
8
Low
pressure
protection
9
Fault in compressor
sensor
10
Overvoltage
protection
Overheat, overcurrent or
short-circuit
Current sensor is broken or
compressor is not started.
Compressor
temperature
>120°C
Current >17A
Short-circuit/open-circuit
Short-circuit/open-circuit
ROM is broken.
Voltage >270V
Heat exchange temperature
of outdoor unit >72°C
E2ROM is broken.
Possible causes
Overheat,
overcurrent
or short-circuit
Current sensor is broken or
compressor is not started.
(reserved)
Compressor
temperature >120°C
Current >17A
ambient
Short-circuit/open-circuit
heat
Short-circuit/open-circuit
Gas is inadequate.
(reserved)
Voltage >270V
>a__WcU[S^ <[c >a`V[e[a`Wc
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
Off
On-off
LED4
LED3
Status
Status
Off
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
On
Off
-291-
1
Fault with
outdoor
unit
2
4
5
6
7
8
10
12
14
LED2
LED1
Remarks
Status Status
On
Fault
Off
with
outdoor
On
Off
unit
On
On
Off
Off
On
Off
On
Off
On
On
Off
Off
On
Off
On
Off

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents