Haier AU282AHBEA Service Manual page 270

Hide thumbs Also See for AU282AHBEA:
Table of Contents

Advertisement

Ports on PCB functions for AU242AHBEA~AU88NATBEA
CN1 : second side of transformer
CN2 : high pressure switch
CN3 : outdoor ambient temperature sensor
CN4 : primary side of transformer
CN5 : control port of 4-way valve
CN6 : control port 2 of compressor ( not available for some models)
CN7 : control port 2 of compressor 1
CN8 : control port 2 of fan motor (not available for some models)
CN9 : control port 1 of fan motor
CN10 : low pressure switch
CN11 : compressor discharging temp. sensor
CN12: outdoor coil temperature sensor
S : connection port for communication between indoor and outdoor
L1 、 L2 、 L3 : power supply terminal(herein, no L2, L3 for single phase compressor)
N : port for neutral wire
TEST : port for compulsory running, herein, on ZR side, short connecting the two pins
can enter the compulsory heating; on ZL side, short connecting the two pins can enter
the compulsory cooling.
CT1 : current detector
LED1 : outdoor LED