Duct Fittings - Monogram ZV48T Installation Instructions Manual

30", 36" and 48" professional vent hoods
Table of Contents

Advertisement

DUCT FITTINGS

Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
Note: Do not exceed maximum permissable
equivalent lengths!
Maximum recommended duct
Flexible ducting:
the equivalent feet values in the table
duct should be straight and smooth
and extended as much as possible.
Any home ventilation system, such as a
Note:
naturally vented systems. To minimize the chance
published by NFPA and ASHRAE. When applicable,
install any makeup (replacement) air system in
Visit GEAppliances.com
solutions.
Hoods Are Equipped
* Hoods are supplied with a 10"
round transition. A locally
supplied transition is required
for other sizes.
Note: Outlet on top of hood is
8-1/8" x 8".
*Actual length of straight duct plus duct
are based on actual tests conducted
requirements for good venting performance with any
ventilation hood.
8
Advance Planning
Duct Piece
10" round
to 8" round
Round,
straight
3-1/4" x 10"
3-1/4" x 12" straight
90° elbow
45° elbow
3-1¦4" x 12"
3-1/4" x 10"
90° elbow
3-1/4" x 10"
3-1/4" x 12"
45° elbow
3-1/4" x 10"
3-1/4" x 12"
10" round transition
to 3-1/4" x 10" or
3-1/4" x 12"
3-1/4" x 10" or
3-1/4" x 12" to
10" round transition
10" round to 3-1/4" x 10"
3-1/4" x 12" transition
90° elbow
3-1/4" x 10"
3-1/4" x 12" to 10" round
transition 90° elbow
Round
wall cap
with damper
3-1/4" x 10"
3-1/4" x 12" wall cap
with damper
Round
roof cap
Equivalent
Quantity
Length*
Used
5 ft.
1 ft.
(per foot length)
1 ft.
(per foot length)
8" Dia. 17 ft.
10" Dia. 24 ft.
8" Dia. 10 ft.
10" Dia. 14 ft.
15 ft.
14 ft.
8 ft.
9 ft.
33 ft.
36 ft.
9 ft.
6 ft.
16 ft.
13 ft.
9 ft.
8 ft.
8" Dia. 32 ft.
10" Dia. 41 ft.
24 ft.
26 ft.
8" Dia. 44 ft.
10" Dia. 56 ft.
Total Duct Run
Total
Length
49-80151-8