Advertisement

3.
Precisely measure both X-axis and Y-axis lines. Better accuracy
in measurement equals better calibration.
4.
Measure both sides and the top and bottom of the box.
X1
~40 in.
Figure 32. The Calibration Box and measurements.
5.
Take the average of the horizontal (Y) values by adding them
together and dividing by 2. Repeat this procedure for the verti-
cal (X) values.
Example:
If X1 = 39.750 in. and X2 = 39.700 in.
The sum is 79.450 in. (39.750 in. + 39.700 in. = 79.450 in.).
The average is 39.725 in. (79.450 in. / 2 = 39.725 in.)
The X calibration value is the average, 39.725 in.

Enter the Calibration Data:

1.
Enter the measured values in the boxes in the Calibration win-
dow. Make sure the SmarTrac is in START mode (green LED).
Select the Set Calibration button.
2.
The signcutter will send the calibration values and the new
Calibration Setting will be displayed in the boxes in the
window.
3.
Click on Done when finished.
Y1
X2
Y2
Chapter 5: Routine Maintenance
51