4.3.4.

CHECKING THE AUTOMATIC STARTER

Check that the automatic starter piston is not scored or
oxidized.
Check that the piston can run smoothly into its mount.
Check that the piston seal is not out of shape.
The starter must be switched on and off depending on
the room temperature.
Measure the piston jut, as shown in the figure, and
check the corresponding value.
Make sure that the starter is set to room temperature.
Jut value: 12.5 ÷ 13 mm at about 20°C
The starter will have to switch progressively off
means of the electric heating.
Check starter resistance with the starter set to room
temperature.
Resistance: about 30 ohm
Using a 12 V battery, feed the automatic starter and
check that the piston reaches max. jut.
Max. jut: 18.5 ÷ 19 mm
Max. time: 5 min
Heating real time depends on room temperature.
In case of juts, resistances or times different from the
recommended ones, change the starter.
Fit starter to carburetor. Take care to correctly position
the OR-seal, install the knurled plate on the starter,
and tighten the two screws (1).
Aim the starter as shown in the figure.
Fit the protective cover.