Atlantic 125 - APRILIA ATLANTIC 125 Workshop Manual

Hide thumbs Also See for ATLANTIC 125:
Table of Contents

Advertisement

ATLANTIC 125 - 200

STARTER RELAY TEST
Disconnect the two-way connector (1) (coloured white).
Release the relay (2) from its mount.
Slip off the two rubber gaiters (3-4).
Disconnect the wires from their respective terminals on
the relay (2).
Feed 12 V to the two terminals inside the connector (1)
at the relay end.
Check for continuity across the two contact screws on
the relay (2) using the multimeter set to the Ohm
range.
Correct reading when relay is fed: 0 ohm
Correct reading when relay is not fed: ∞ ohm
Change the relay (2) when the readings found deviate
from the specified values.
STARTER MOTOR TEST
Remove the starter motor and connect it to a 12 V
battery in good working order.
If the motor is not operating properly, check for brush
wear and inspect slip ring.
ELECTRICAL SYSTEM