<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
(1) Remove the front panel.
Fully open the front panel. Disengage the support
arm located in the upper center while pushing its
handle leftwards, and then remove the front panel
toward you.
(2) Remove the terminal cover and cord clamp.
(3) Insert the connecting cable (according to local
codes) into pipe hole on the wall.
(4) Take out the connecting cable through the cable
slot on the rear panel so that it is exploded by about
15 cm long in the front side.
(5) Insert the connecting cable fully into the terminal
block and secure it by screw tightly.
(6) Tightening torque:1.2 N•m (0.12 kgf•m)
(7) Secure the connecting cable with the cord clamp.
(8) Fix the terminal cover and front panel on the in-
door unit.
CAUTION
• Be sure to refer the wiring system diagram la-
beled inside the front panel.
• Check local electrical codes and also any spe-
cific wiring instructions or limitation.
Terminal block
Terminal
Connecting
cover
cable
Screw
Cord
clamp
1
2
Screw
Screw
Connecting cable
The connecting
cable doesn't
need the earth line.
Fig. 8-4-9
<Stripping length of connecting cable>
10mm
2
1
For two conductor cable system
NOTE :
• Use stranded wire only.
• Wire type:More than H05 RN-F
<How to install the front cabinet on the indoor unit>
Install the front cabinet through the opposite order of
"How to remove the front cabinet".
When the panel is removed and mounted again, take
the following actions:
After fastening the two screws, one each at the left
and right of the air outlet, be sure to push the upper
center
right end
1
center
of the air outlet, and confirm that no gap is
4
left between the front cabinet and the rear plate.
• If cooling (dry) operation is made without push-
ing the air outlet, dew can be deposited on the
front cabinet surface. In addition a gap between
the front cabinet and the rear plate will become
wider, spoiling the appearance.
Push
3
– 25 –
40mm
Connecting cable
The connecting
cable doesn't
need the earth line.
Fig. 8-4-10
, left end
2
3
Push
1
4
Push
Fig. 8-4-11
and the lower
Push
2