Approved Vent Configurations; Restrictor Position; Exhaust Restrictor Adjustment - Travis Industries 564 SS GSR2 Installation Manual

Vented gas fireplace heater
Hide thumbs Also See for 564 SS GSR2:
Table of Contents

Advertisement

Approved Vent Configurations

Restrictor Position

Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor Adjustment

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust
restrictor is removed.
© Travis Industries
Installation
(for qualified installers only)
(closed) #6
# 5
# 4
# 3
# 2
# 1
(open - stock position) # 0
4141013
The exhaust restrictor is shipped
in postion # 0. If the restritor is
required in a different postion,
remove the screws, re-position
the restrictor (see the illustration
below), and replace the screws.
In this example, the restrictor is
set in position # 3.
Back of Firebox
100-01393
23

Advertisement

Table of Contents
loading

Table of Contents