10-1. Installation Diagram of Indoor and Outdoor Units
5
Filter
3
2
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (− ) positions.

10. INSTALLATION PROCEDURE

6
Filter
8
4
Pan head
wood screw
Batteries
Wireless remote control
2 Wireless remote controller
Hook
Installation
1
plate
Shield pipe
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension
drain hose
(Not available,
provided by installer)
3 Batteries
– 47 –
FILE NO. SVM-11029
For the rear left and left piping
Wall
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
Do not allow the drain hose to
get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected to the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Rear
Bottom
left
right
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
Left