Hi-Power Mode; Fil Ter Indicator; S Hort Time - Toshiba RAS-16SKV2-E1 Service Manual

Toshiba split type air conditioner service manual
Table of Contents

Advertisement

Item
18. Hi-POWER
([Hi-POWER] button on the remote controller
Mode
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi-
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
• The indoor unit operates in according to the
2. Cooling operation
• The preset temperature drops 1ºC
3. Heating operation
• The preset temperature increases 2ºC
4. The Hi-POWER mode can not be set in Dry
operation
19. FILTER
When the elapsed time reaches 1000 hours after
Indicator
air conditioner operation, the FILTER indicator lights.
After cleaning the filters, turn off the FILTER indicator.
How to Turn Off FILTER Indicator
Press [RESET] button on the indoor unit.
NOTE :
If [RESET] button is pushed while the FILTER indicator
is not lit, the indoor unit will start the automatic
operation.
20. Short Timer
In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
Operation flow and applicable data, etc.
current operation.
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
PRESET
FAN
ONE-TOUCH
MODE
·
COMFORT
QUIET
SLEEP
SWING
FIX
Hi-POWER POWER-SEL
TIMER
CLR
ON
OFF
·
SLEEP
SET
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
j
k
l
m
m
n
n
40
FILE NO. SVM-11029
Description
Press [
] button to turn the unit OFF.
Set the operation mode or plasma air
purifier on the remote control without
sending the signal to the unit.
Use the tip of the pencil to push the
[CHK] button and hold, "00" will show
on display, them press [SET] button
to make "00" disappear.
Press [
] button to turn the unit ON.
When short timer is activated, all
setting on the remote operates
immediately, besides, all indicatiors on
front panel turns ON continuously for
3 seconds.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-16sav2-e1

Table of Contents