ADVANCE PLANNING

Ductwork Planning
• These vent hoods are equipped for 10" round ductwork.
For best performance, use 10" round ductwork on the
48" wide hoods. 30" and 36" hoods may be transitioned
to 8" round.
• This hood may be vented vertically through upper cabi-
nets, soffit or ceiling. A duct transition piece is supplied
for vertical exhaust. Use locally supplied elbows to vent
horizontally through the rear wall.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should
not exceed 150 ft. equivalent length for any duct con-
figurations.
• Refer to "Duct Fittings" chart to compute the
maximum permissible length for duct runs to the out-
doors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Wall Framing for Adequate Support
• These vent hoods are heavy. Adequate structural sup-
port must be provided. Hoods must be secured to verti-
cal studs in the wall.
• It is strongly recommend that the vent hood with
duct cover be on site before final framing and wall
finishing. This will also help to accurately locate the
ductwork and electrical service.
Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available
to fit all models. The duct cover conceals the ductwork
running from the top of the hood to the ceiling or soffit.
Stack one or more duct covers over the top of the hood
to reach your ceiling height.
Advance Planning

POWER SUPPLY

IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROP-
ERLY GROUNDED.
AVERTISSEMENT –
SONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTE-
MENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before begin-
ning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or pre-
vailing local codes and ordinances.

Electrical supply

These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker
or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above require-
ments, call a licensed electrician before proceeding.
• Route house wiring as close to the installation
location as possible on the back wall or ceiling.
• Connect the wiring to the house wiring in
accordance with local codes.

Grounding instructions

The grounding conductor must be connected to
a ground metal, permanent wiring system, or an equip-
ment-grounding terminal or lead on the hood.
WARNING:
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil de mise à la terre peut
causer un choc électrique. En cas de doute, consulter un
électricien qualifié ou un technicien pour déterminer si
l'appareil est à la terre.
6