Mhz Deviation Adjustment (Vc-214 Board) - Sony Handycam Vision CCD-TRV66E Service Manual

Sony video camera recorder service manual
Hide thumbs Also See for Handycam Vision CCD-TRV66E:
Table of Contents

Advertisement

1. 1.5 MHz Deviation Adjustment (VC-214 board)

Sets the spectrum of the L-ch ((L+R)/2 signal) level modulated
during recording. If deviated, the crosstalk signal of the audio signal
will occur and the audio level will drop during both playback and
recording.
Mode
VTR recording
Signal
Input the AFM DEV jig output signal to
the left and right audio input terminal
Measurement Point
CH1: AFM DEV jig TP31
CH2: AFM DEV jig TP3
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
62
Specified Value
The level difference between CH1 signal
and CH2 signal should be minimum.
Connection:
1)
Connect TP24 ,TP25 and TP26 of the AFM DEV jig to CN910
of the VC-214 board.
TP24(GND) ................ Pin 8 of CN910
TP25(REC RF) ........... Pin 0 of CN910
TP26(RF SWP) .......... Pin !¡ of CN910
2)
Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
3)
Connect TP28(DC), TP27(GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
4)
Set the AFM DEV jig switches to the following positions.
S1 ........................... BIL Position
S2 ........................... PAL Position
S3 ........................... SIN Position
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "4-3, 3. Bit value
discrimination" of "5-4. Service Mode").
3)
Set to recording mode. (Use the wireless remote commander
of 8mm VCR.)
Adjusting method :
1)
Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2)
Set the oscilloscope to the ADD mode and CH2 to the INV
(invert) mode.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: F, address: 62, change the data and minimize the
audio signal level difference (A).
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of "Preparations only for the model without REC switch".
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Approx. 2msec
Fig. 5-3-20.
ADD mode
CH2 INV mode
A
2. 1.7 MHz Deviation Adjustment (VC-214 board)
Sets the spectrum of the R-ch ((L-R)/2 signal) level modulated during
recording. If deviated, the crosstalk signal of the audio signal will
occur and the audio level will drop during both playback and
recording.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Connection:
1)
Connect TP24 ,TP25 and TP26 of the AFM DEV jig to CN910
of the VC-214 board.
TP24(GND) ................ Pin 8 of CN910
TP25(REC RF) ........... Pin 0 of CN910
TP26(RF SWP) .......... Pin !¡ of CN910
2)
Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
3)
Connect TP28(DC), TP27(GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
4)
Set the AFM DEV jig switches to the following positions.
S1 ........................... BIL Position
S2 ........................... PAL Position
S3 ........................... INV Position
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "4-3, 3. Bit value
discrimination" of "5-4. Service Mode").
3)
Set to recording mode. (Use the wireless remote commander
of 8mm VCR.)
Adjusting method :
1)
Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2)
Set the oscilloscope to the ADD mode and CH2 to the normal
mode.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: F, address: 63, change the data and minimize the
audio signal level difference (A).
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of "Preparations only for the model without REC switch".
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Approx. 2msec
5-45
VTR recording
Input the AFM DEV jig output signal to
the left and right audio input terminal
CH1: AFM DEV jig TP32
CH2: AFM DEV jig TP2
Oscilloscope
ADD mode
CH2 normal mode
F
63
The level difference between CH1 signal
and CH2 signal should be minimum.
A
Fig. 5-3-21.