Hard Disk Drive Bays - Intel SSR212CC Technical Product Specification

Storage system
Hide thumbs Also See for SSR212CC:
Table of Contents

Advertisement

Intel® Storage System SSR212CC
4.1

Hard Disk Drive Bays

The Storage System SSR212CC chassis can support up to twelve carrier-mounted SATA, 3.5
inch x 1 inch, hard disk drives. The SATA drives may be "electrically" hot-swapped while the
system power is applied, i.e., before or during POST.
NOTE:
1) Drive bays 1 thru 6 are controlled by a single Intel® RAID Controller SRCS28X, while drive bays 7
thru 12 are controlled by a second Intel® RAID Controller SRCS28X
2) To correspond with cable connection across both SRCS28X SATA HBAs, all drives must be
populated in order, from left to right, top to bottom, in drive bay 1 thru drive bay 12, sequentially
distributed across both SRCS28X SATA HBA's. For example, if only 8 drives are installed, 6
drives should be inserted into bays 1 thru 6, and two drives inserted into bays 7 and 8.
1
5
9
3) HDD labels are provided in your Storage System SSR212CC shipping container to number the
drives 1 thru 12.
4)
If a failed drive needs replacing, it should be replaced with the exact same manufacturer, model,
and size.
Revision 1.2
2
6
10
.
3
7
11
Chassis Bays
4
8
12