Installation; Technical Specifications - Lincoln Electric IDEALARC DC-600 Operator's Manual

Hide thumbs Also See for IDEALARC DC-600:
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS - IDEALARC DC-600
Standard Voltage
208/230/416/460/575/3/60
Duty Cycle
100%
60%
50%
Mode
Constant Current
Constant Voltage
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input Voltage /
Frequency
208/60
230/60
416/60
460/60
575/60
Height
30.75 in.
(781 mm.)

INSTALLATION

INPUT - THREE PHASE ONLY
RATED OUTPUT
OUTPUT
Current
Range
90 to 850 Amps
70 to 850 Amps
Fuse
Input Ampere
(Super Lag)
or Breaker Size
175
175
100
90
80
PHYSICAL DIMENSIONS
Width
22.25 in.
(567 mm.)
IDEALARC DC-600
Input Current at Rated Output
125/113/63/57/45
AMPS
600
680
750
Maximum Open
Circuit Voltage
72 VDC
55 VDC
Type 75
Rating on
Copper Wire in
Nameplate
Conduit AWG
(IEC) Sizes
125
2 (35mm
113
2 (35mm
63
6 (16mm
57
6 (16mm
45
6 (16mm
Depth
39.0 in.
(988 mm.)
Volts at Rated Amps
44
44
44
Auxiliary Power
115 VAC, 8 Amps
Type 75
o
C
o
C
Copper Ground
Wire in Conduit
AWG (IEC) Sizes
2
)
6 (16 mm
2
)
2
)
6 (16 mm
2
)
2
)
8 (10 mm
2
)
2
)
8 (10 mm
2
)
2
)
8 (10 mm
2
)
Weight
522 lbs.
(237 kg.)
A-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents