7-2. Operation Data

<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition 5 m
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
11 to 13
0.8 to 1.0
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
2.6 to 2.8
41 to 43
– 19 –
FILE NO. SVM-12039
Indoor
fan mode
T2 (°C)
46 to 48
High
Indoor
fan mode
T2 (°C)
0 to 2
High
Outdoor
Compressor
fan mode
revolution
(rps)
79
High
Outdoor
Compressor
fan mode
revolution
(rps)
83
High