2-3. Operation Characteristic Curve
<Cooling>
8
7
6
5
4
3
2
1
0
0
10
20
30
40
Compressor Speed (rps)
2-4. Capacity Variation Ratio According to Temperature
<Cooling>
105
100
95
90
85
80
75
70
Capacity ratio 100% is 3.5 kW
65
60
55
50
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Conditions
o
Indoor : DB 27
C/WB 19
Outdoor : DB 35
Air Flow : High
Pip Length : 5m
Voltage : 230V
50
60
70
80
90 100 110 120
Conditions
Indoor:DB27℃/WB19℃
Indoor air flow:High
Pipe length:5m
Voltage : 230V
(℃)
Outdoor temp.
<Heating>
8
7
6
5
4
3
2
o
C
o
C
1
0
0
<Heating>
120
100
80
60
40
20
0
-15
– 5 –
FILE NO. SVM-12039
10
20
30
40
50
60
Compressor Speed (rps)
Capacity ratio 100% is 4.2 kW
Condition
Indoor:DB20℃
Indoor air flow:High
Pipe length:5m
Voltage : 230V
-10
-5
Outdoor temp. (℃)
Conditions
o
Indoor : DB 20
C
o
o
Outdoor : DB 7
C/WB 6
C
Air Flow : High
Pip Length : 5m
Voltage : 230V
70
80
90 100 110 120
0
5
10