Quasonix Compact RDMS Installation And Operation Manual page 32

Telemetry receiver
Table of Contents

Advertisement

 
 
Mnemonic
Name
TO F
Tape Output
Frequency
TO T
Tape Output
Source
VE
Version
18
Quasonix, Inc.
Description
Sets the carrier frequency of
the pre-detection complex
Tape Output
Examples:
TO F 0 Sets the Tape
Output Frequency to Off
(carrier frequency = 0 MHz)
TO F 1 Sets the Tape
Output Frequency to a
specific frequency number
Value range is 0.000 to
20.000 MHz
Sets the test output to a
Tape source;
Enables or Disables the pre-
detection complex baseband
as the tape output source
When enabled (T=1), pre-
detection complex baseband
is selected as the source of
data to send on I and Q
analog outputs
When disabled (T=0), the I
and Q analog outputs
(frequency/phase
information) are restored to
their normal defaults which
vary by mode
Examples:
TO T 0 Sets the Tape
Output Source to disabled
TO T 1 Sets the Tape
Output Source to enabled
Report the current Firmware
(software) version
information for the receiver
TM
Compact RDMS
Option (s)
Required
Advanced
Command
37
Advanced
Command
37
Advanced
Command
Standard
Basic
Telemetry Receiver
Basic or
Mode
Restriction
PCM/FM
PCM/FM
None

Advertisement

Table of Contents
loading